Questions and Answers

  • D
    davidbarnesAug 14, 2025
    What to do if Chint Power Inverter shows a Grid Fault?
    • R
      Ryan NielsenAug 14, 2025
      If the Chint Power Inverter displays a 'System Fault' due to a 'Grid Fault,' first wait 30 seconds to see if the grid returns to normal, as the inverter will automatically restart. If the issue persists, ensure that your grid voltage and frequency meet the required specifications. If problems continue, further assistance is needed.
  • G
    garciawilliamAug 18, 2025
    Why Chint Power CPS SC1.5KTL showing System Fault No Utility?
    • T
      Tina SmithAug 18, 2025
      If your Chint Power Inverter is showing a 'System Fault' caused by 'No Utility', the grid may not be connected. Check the grid connection cables and verify the grid's usability.
  • A
    alex54Aug 21, 2025
    How to fix Isolation Fault on Chint Power CPS SC1.5KTL Inverter?
    • L
      Linda LawsonAug 21, 2025
      If your Chint Power Inverter is experiencing a 'System Fault' due to an 'Isolation Fault', check that the impedance between PV (+) & PV (-) and the PV-Inverter earth is greater than 2MΩ. If the problem continues, further assistance is needed.
  • N
    Nicole JohnsonAug 25, 2025
    What to do if Chint Power Inverter shows Over Temperature Inverter Failure?
    • J
      James BestAug 25, 2025
      If your Chint Power Inverter displays an 'Inverter Failure' due to 'Over Temperature,' it means the internal temperature is too high. Try to reduce the ambient temperature or move the inverter to a cooler environment. If the problem persists, further assistance is needed.
  • D
    Daniel Myers Jr.Aug 27, 2025
    How to resolve Impedance Fault on Chint Power Inverter?
    • C
      Charles MckayAug 28, 2025
      If the Chint Power Inverter displays a 'System Fault' due to 'Impedance Fault,' it indicates that the grid impedance is higher than the permissible value. Wait 30 seconds to see if it resolves itself. Check the wiring between the inverter and the grid, replacing wires with larger ones if necessary. You can also adjust the impedance parameter using the Data Program. If the issue continues, further assistance is needed.
  • K
    Kimberly WhitakerAug 31, 2025
    Why Chint Power CPS SC1.5KTL showing PV over Voltage Inverter Failure?
    • B
      Brendan MitchellAug 31, 2025
      If your Chint Power Inverter is showing 'Inverter Failure' caused by 'PV over Voltage', check the open PV voltage to see if it is greater than or too close to 500V (450V for CPS SC1.5KTL). If the PV voltage is less than 500 V (450 V,) and the problem persists, further assistance is needed.
  • B
    brittanyrothSep 3, 2025
    What to do if Chint Power CPS SC1.5KTL displays System Fault Ground I Fault?
    • R
      Rebecca SummersSep 3, 2025
      If your Chint Power Inverter is displaying a 'System Fault' due to 'Ground I Fault,' it means the ground current is too high. Unplug the inputs from the PV generator and check the peripheral AC system. After clearing the cause, re-plug the PV panel and check the inverter status. If the problem persists, further assistance is needed.
  • P
    Patrick HendersonSep 7, 2025
    How to fix Relay Failure on Chint Power Inverter?
    • D
      Dennis CaseySep 7, 2025
      If your Chint Power Inverter shows 'Inverter Failure' due to 'Relay Failure', disconnect ALL PV (+) or PV (-), wait a few seconds until the LCD switches off, then reconnect and check again. If the message reappears, further assistance is needed.
  • J
    Jason CollinsSep 10, 2025
    What to do if Chint Power Inverter shows Consistent Fault Inverter Failure?
    • S
      sullivannatalieSep 10, 2025
      If your Chint Power Inverter displays an 'Inverter Failure' due to a 'Consistent Fault,' disconnect PV (+) or PV (-) from the input and restart the inverter. If it does not work, further assistance is needed.

Chint Power CPS SC1.5KTL Specifications

General IconGeneral
ModelCPS SC1.5KTL
CategoryInverter
Rated Power1.5kW
Number of MPP Trackers1
Nominal AC Power1.5 kW
Rated Output Power1.5kW
Output Frequency50/60 Hz
Power Factor>0.99
Efficiency97.5%
Cooling MethodNatural convection
Protection DegreeIP65
Warranty5 years
Output Voltage230V
Rated Output Voltage230 V
CommunicationWiFi
Operating Temperature Range-25~+60°C