CHINT NA1-1000X User Manual

CHINT NA1-1000X
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Air Circuit Breaker
Leading every step, reliable new height

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the CHINT NA1-1000X and is the answer not in the manual?

CHINT NA1-1000X Specifications

General IconGeneral
Rated Current (In)1000 A
Rated Voltage (Ue)690 V AC
StandardIEC 60947-2
Mounting TypeFixed
Rated Operational Voltage400 V AC
Rated Insulation Voltage800 V
Trip Unit TypeElectronic
Poles3P
Breaking Capacity (Icu)50kA/65kA/85kA (depending on voltage)
Rated Ultimate Short-Circuit Breaking Capacity (Icu)50kA/65kA/85kA (depending on voltage)

Summary

NA8G Technical Parameters and Capacity

4. Main Technical Parameters

Presents comprehensive technical specifications and parameters for the NA8G series air circuit breakers.

NA8G Secondary Circuit Wiring

Connection Diagram for the Secondary Circuit of NA8G-1600 with Standard Type Intelligent Controller

Detailed wiring diagram for NA8G-1600 using a standard intelligent controller.

Intelligent Controller Features and Operation

7. Intelligent Controller and Protective Characteristics

Covers the features, interface, and protective characteristics of the intelligent controllers.

7.1 User Interface of the Standard Type Controller

Explains the buttons, indicators, and display of the standard controller's user interface.

7.2 Default Interface and Operation Method for the Standard Type Controller

Describes the default display and basic operation steps for the standard controller.

7.3 User Interface of the Multifunctional Controller

Details the buttons, indicators, and display of the multifunctional controller's user interface.

7.4.3 Structure of the Protection Parameter Setup Menu

Describes the organization of protection parameter settings within the controller.

7.6 Characteristic Parameters of the Standard Type Intelligent Controller

Presents characteristic curves and parameters for the overcurrent and earth fault protection of the standard intelligent controller.

7.6.1 Long Time-Delay Overcurrent Protection Characteristic

Details the characteristic curves and settings for long time-delay overcurrent protection.

7.6.2 Short-Circuit Short Time-Delay Overcurrent Protection Characteristic

Explains the characteristics and settings for short-circuit short time-delay overcurrent protection.

7.6.3 Short-Circuit Instantaneous Overcurrent Protection

Describes the characteristics and setting parameters for short-circuit instantaneous overcurrent protection.

7.6.4 Single-Phase Earthing Fault Protection

Outlines the characteristics and setting methods for single-phase earthing fault protection.

NA8G Accessories and Functions

8. Accessories

Lists and describes various accessories available for the NA8G series air circuit breakers.

NA8G Installation and Troubleshooting

10. Common Faults and Troubleshooting

Provides a guide to common malfunctions and their troubleshooting methods for NA8G breakers.

No. 1 Breaker Tripping (Fault Indicator On)

Addresses issues related to breaker tripping and the fault indicator status.

No. 2 Breaker Fails to Close

Covers troubleshooting steps when the breaker fails to close properly.

No. 3 Breaker Trips After Closed

Explains reasons and solutions for tripping immediately after closing.

No. 4 Breaker Fails to Open

Addresses issues where the breaker fails to open as expected.

No. 5 Breaker Fails to Store Energy

Details troubleshooting for when the breaker fails to store energy.

NA1 Series General Information and Structure

NA1 Air Circuit Breaker Components

Provides an exploded view and identification of the main components of the NA1 series air circuit breaker.

NA1 Technical Parameters and Dimensions

NA1 Secondary Circuit Wiring and Controller

6. Secondary Circuit Wiring

Provides wiring diagrams for the secondary circuits of NA1 models.

Intelligent Controller of NA1 Series

Introduces the intelligent controller for the NA1 series, covering its features and UI.

14 Protection Features of Intelligent Controller

Details the protection features and characteristics of the intelligent controllers.

14.4 Specifications of Characteristics

Details the electrical and protection characteristics of the NA1 intelligent controllers.

14.4.1 Over-current Protection Characteristic Curve

Presents characteristic curves for overload, short delay, and instantaneous overcurrent protection.

14.4.2 Overload Long Time-Delay Protection

Describes the operating characteristics for overload long time-delay protection.

14.4.4 Short-Circuit Instantaneous Protection

Details the operating characteristics for short-circuit instantaneous protection.

14.4.5 Earthing Protection

Outlines the characteristics and operating modes for earthing protection.

NA1 Accessories and Installation

NA1 Maintenance, Troubleshooting, and Ordering

16. Maintenance and Overhaul of Circuit Breaker

Provides essential safety precautions and procedures for maintaining and overhauling circuit breakers.

17. Common Failure Causes and Solutions

Provides a troubleshooting guide for common failures encountered with the circuit breaker.

17.1 Troubleshooting Logic

Presents a flowchart to diagnose and resolve common circuit breaker malfunctions.

18. Regular Malfunction and Solutions

Lists common malfunctions and provides corresponding maintenance methods.