1. General

1.1 Application scope

Describes the application scope of the NA1 series air circuit breaker, including its voltage and current ratings.

2. Operating conditions

3. Product structure

4. Main technical parameters

4.1 Main technical parameters

Presents detailed technical specifications including electrical, mechanical, and physical data of the NA8G series.

4.2 Capacity-reducing usage

Discusses how the current-loading capacity changes with different ambient temperatures and altitudes.

6. Secondary circuit wiring

Connection diagram for the secondary circuit of NA8 G-1600 with standard type intelligent controller

Illustrates the wiring diagram for the secondary circuit of NA8G-1600 with a standard controller.

Connection diagram for the secondary circuit of NA8 G-1600 with multifunctional type intelligent controller

Illustrates the wiring diagram for the secondary circuit of NA8G-1600 with a multifunctional controller.

7. Intelligent controller and protective characteristics

7.1 User interface of the standard type controller

Describes the user interface elements and buttons for the standard type intelligent controller.

7.2 Default interface and operation method for the standard type controller

Explains the default display and operation sequence for the standard type intelligent controller.

7.3 User interface of the multifunctional controller

Details the user interface elements and buttons for the multifunctional intelligent controller.

8. Accessories

9. Installation

10. Common faults and troubleshooting

Breaker tripping (fault indicator on)

Provides reasons and maintenance methods for breaker tripping faults indicated by the fault indicator.

11. Ordering specification

4. Main technical parameter

7. Installation

13. Selectivity protection

14. Protection Features of intelligent controller

14.1 M;H and 3 M;3 H intelligent controller UI

Describes the User Interface (UI) for M/H and 3M/3H intelligent controllers.

15. Accessories

16. Maintenance and Overhaul of Circuit Breaker

17. Common Failure Causes and Solutions

17.1 Troubleshooting logic

Presents a flowchart for diagnosing common circuit breaker failures.

17.2 Faulty tripping analysis

Explains how to identify failure causes through the intelligent controller's indication.

18. Regular malfunction and solutions

Tripping of circuit breaker

Lists common reasons for tripping faults and their corresponding maintenance methods.

The breaker cant be closed

Details faults that prevent the breaker from closing and their solutions.

Circuit breaker cant be opened

Outlines common faults preventing the circuit breaker from opening and their repair methods.