Number of poles
Protection function
Model
Rated current In (A)
Installation mode
Intelligent Controller
□
Standard
(Default
configuration)
M type
□
Communication
type
(Optional
configuration)
3H-type
Notes:
Protection
function
Settable
range and
conventional
factory tuning
Controller power
Auxiliary functions
Optional function
1. Ammeter
function
2. Self-diagnostic
function
3. Tuning function
4. Test function
5 Display function
□
□ Frequency display
□ Power Factor show
□ Active power display
□ Load monitoring
function
Note: For the specific
optional function, refer
to List of controller
functions in the sample
(The cost of optional
functions will be
calculated additionally).
Voltage display
□ Drawout type
□Fixed type (Note: no fixed type when In> 4000A)
□ Three poles □Four poles
□ □ □NA1-2000X NA1-2000XN NA1-2000XH □ □NA1-3200X NA1-3200XN
NA1-4000X
□ □ □
□1250 □1600 □2000
630 800 1000 □ □
□3200
2000 2500
□NA1-1000X
□ □ □
□800 □1000
200 400 630
□4000
□ □
□6300(no four poles)
4000 5000
Undervoltage
release (default
configuration)
Shunt release
Electric motor
Interlock device
(surcharge)
Accessories
(surcharge)
Electrical accessories
Special requirements
The main circuit
connection
NA1-1000X~6300X Ordering specification
Closing electromagnet
Note: The casing current, rated current and auxiliary control voltage must be specified when ordering!
□
2
Tel.:0577-62877777-6213 Fax :0577-62877777-6288
Note: 1) Please mark “√” or fill figure in the relative ” ” if no mark, we will provide according to conventional.
Note: ) The operational fuction of the intellgent controller and special requirements require additional costs.
1. Ir overload long delay, Isd short-circuit short delay inverse
time + definite time, Ii transient short-circuit, Ig single-phase
grounding 4-section protection
2. □ Ir overload long delay, Isd definite time short-circuit short
delay,Ii transient short-circuit, Ig single-phase grounding 4-section
protection
□
1. Ir overload long delay short-circuit short delay inverse time
+definite time Ii transient short-circuit, Ig single-phase grounding
4-section protection
2. □ Ir overload long delay, Isd definite time short-circuit short delay,
Ii transient short-circuit, Ig single-phase grounding 4-section protection
3. □ with PROFIBUS-DP communication protocol
□ with MODBUS communication protocol
□ Isd
1. Ir overload long delay, short-circuit short delay inverse
time + definite time, Ii transient short-circuit, Ig single-phase
grounding 4-section protection
2. □ Ir overload long delay, Isd definite time short-circuit short
delay,Ii transient short-circuit, Ig single-phase grounding 4-section
protection
□ Isd
□
Multifunctional
(Optional
configuration)
3M type
Customer: Tel: Date:
Quantity:
NA1-6300X
NA1-4000X NA1-3200X NA1-2000X NA1-1000X
Ir long delay current setting range: (0.4 to 1) In
Overload 1.5Ir action time setting range: 15,30,60 ...... 480s
Ii instantaneous current setting range: 1.5In ~ 50kA/65kA/75kA
! Conventional factory tuning: 12In [Note: 3M, 3H for (1.5In~50kA/65kA/75kA)]
Ig earthing protection current setting range: (0.2 to 0.8) In; the earthing protection time setting range: (0.1to0.4)s
! Conventional factory setting: 0.5 In; OFF
□AC380V,□AC400V,□AC220V,□AC230V,□AC127V,□DC220V,□DC110V
□AC380V,□AC400V,□AC220V,□AC230V,□AC127V,□Order_____V ,□Non-undervoltage
□ Instantaneous □ delay, s; □ Resistance capacity loss release delay (1,3,5) s, and optional non-adjustable
□AC380V,□AC400V,□AC220V,□AC230V,□AC127V,□DC220V,□DC110V
Mechanical linkage: Link interlock □ Cable interlock□
Door interlock: Switch body position door interlock Switch on/off state door interlock (drawer-type) □ □
Button lock: Panel products on/off button lock □
Key lock: 1 lock 1 key 2 locks 1 key 3 locks 1 key 3 locks 2 keys 5 locks 3 keys pecial custom__lock__ key □ □ □ □ □ □S
External transformer: □External N phase transformer [(3P+N)T type
□ □External leakage zero sequence current transformer (E mode) External ground current transformer (W)
Module: RU-1 relay module □ □ □PSU-1 Power module ST-DP protocol converting module
□ □ □ □ □Position signaling devices ( Test ) Connected Unconnected Mechanical counting device
□ □Horizontal Vertical connection (with L vertical bus-bar) connection (default)
□ horizontalRotation busbar connection (Drawer In ≤ 3200)
□Rotation busbar vertical connection (drawer-type In ≤ 3200)
! Conventional factory setting: short delay current 8Ir ;
! Conventional factory tuning: Short delay action time 0.4s
[Note: 3M, 3H for (1.5 to 15) Ir]
(Optional)
I short delay current setting range: (1.5 to 15) Ir;
short delay action time (0.1 ~ 0.4) s
sd
□AC380V,□AC400V,□AC220V,□AC230V,□AC127V,□DC220V,□DC110V
□AC380V,□AC400V,□AC220V,□AC230V,□AC127V,□DC220V,□DC110V
! Conventional factory tuning: overload 1.5Ir; action 15s
! Conventional factory tuning: overload long delay 1.0In
(Optional)
(Optional)
(Optional)
(Optional)
(Optional)
(Optional)
(Optional)
(Optional)
□ □NA1-6300X NA1-6300XN
4. NA1-1000X operational configuration (additional costs)
Under voltage delayed release; wire-cable mechanical
interlock;
key lock; External current transformer earthing protection;
Vertical busbar; 6 groups changeover contacts;
H type intelligent controller; Phases barrier, position signal.
3. NA1-2000X~6300X operational configuration (additional costs)
Nonadjustable under voltage delayed release (1s, 3s, 5s);
Connecting-rod type mechanical interlock (for drawout type);
Wire-cable mechanical interlock; Button lock; Key lock;
Door interlock'Locking device;
External current transformer earthing protection; Vertical
busbar;
Rotating busbar (IN≤3200);
3NO (normal open) and 3NC (normal close) contacts;
4NO and 4NC contacts; 5 groups changeover contacts;
3 groups changeover contacts; H type intelligent controller;
Position signal; Counter; Protecting cover (NA1-2000);
Double power controller.
2. NA1-1000X fundamental configurations
a. Motor-driven:
Under-voltage instantaneous release;
Shunt release;
Closing electromagnet;
Motor driven operating mechanism;
4 normal open and 4 normal close auxiliary
contacts;
M-type Intelligent Controller;
Closing and breaking push button lock;
Horizontal wiring of main circuit;
Doorcase;
Element of main circuit;
Operating instructions of Air Circuit Breaker;
Packing box;
Drawer seat(Drawout type)
1. NA1-2000X~6300X fundamental configurations
a. Motor-driven:
Under-voltage instantaneous release;
Shunt release;
Closing electromagnet;
4 suits of transform contact;
Motor driven operating mechanism;
M-type Intelligent Controller;
Horizontal wiring of main circuit;
Doorcase;
Element of main circuit;
Operating instructions of M-type Intelligent Controller
Operating instructions of Air Circuit Breaker;
Packing box;
Drawer seat (Drawout type)
Configuration instructions
C
NA1
Air Circuit Breaker
P-104
P-103
NA1
Air Circuit Breaker
b. Manual:
Under-voltage instantaneous release;
4 suits of transform contact;
M-type Intelligent Controller;
Horizontal wiring of main circuit;
Doorcase;
Element of main circuit;
Operating instructions of M-type Intelligent
Controller
Operating instructions of Air Circuit Breaker;
Packing box;
Drawer seat(Drawout type)
b. Manual:
Under-voltage instantaneous release;
4 normal open and 4 normal close auxiliary
contacts;
M-type Intelligent Controller;
Horizontal wiring of main circuit;
Closing and breaking push button lock;
Doorcase;
Element of main circuit;
Operating instructions of Air Circuit Breaker;
Packing box;
Drawer seat(Drawout type)