Using Remote Control
triggers the acquisition of new data before returning data. FETCh returns the
previously acquired data from measurement buffer.
Setting Syntax:
none
Setting Parameters: none
Query Syntax:
FETCh?<PMT>
FETCh?<space><CRD>,<CRD>,<CRD>,…<PMT>
MEASure?
MEASure?<space><CRD>,<CRD>,<CRD>,…<PMT>
Query Parameters: <CRD>,
66201: V, VPK+, VPK-, I, IPK+, IPK-, CFI, W, PF, VA, VAR, FREQ
66202: V, VPK+, VPK-, THDV, I, IPK+, IPK-, IS, CFI, THDI, W, PF, VA,
VAR, ENEG, FREQ
Response Parameters: <NR2>
Example 1:
Query: FETC?<PMT>
Response:
Header on:
66201: :FETCH<space>V<space><NR2>;VPK+<space><NR2>;VPK-<space
><NR2>;I<space><NR2>;IPK+<space><NR2>;IPK-<space><NR2>;
CFI<space><NR2>;W<space><NR2>;PF<space><NR2>;VA<space>
<NR2>;VAR<space><NR2>;FREQ<space><NR2><RMT>
66202: :FETCH<space>V<space><NR2>;VPK+<space><NR2>;VPK-<space
><NR2>;THDV<space><NR2>;I<space><NR2>;IPK+<space><NR2>
;IPK-<space><NR2>;IS<space><NR2>;CFI<space><NR2>;THDI<spa
ce><NR2>;W<space><NR2>;PF<space><NR2>;VA<space><NR2>;
VAR<space><NR2>;ENEG<space><NR2>;FREQ<space><NR2><R
MT>
Header off:
66201:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>; <NR2>;<NR2><RMT>
66202:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>; <NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2><RMT>
Separator 0:
66201:
<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2
>,<NR2>,<NR2>,<NR2><RMT>
66201:
<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2
>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2><RMT>
Separator 1:
66201:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>;<NR2>;<NR2><RMT>
66202:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2><RMT>
5-15

Other manuals for Chroma 66201