Digital Power Meter 66203/66204 User’s Manual
5-24
FETCh[:SCALar]:POWer:PFACtor? {<NR1>}
MEASure[:SCALar]:POWer:PFACtor? {<NR1>}
Type: Channel-Specific.
Description: These queries return the power factor. The return could be -3 or
<NR2>.
-3: Invalid data when OVR, OCR, OCP occur.
Setting syntax: none
Setting parameters: none
Query syntax: FETCh:POWer:PFACtor?<PMT>,
FETCh:POWer:PFACtor?<space><NR1><PMT>,
MEASure:POWer:PFACtor?<PMT>,
MEASure:POWer:PFACtor?<space><NR1><PMT>
Query parameters: <NR1>, 0 ~ 4, 0:All channel, 1~4:Channel 1 ~ Channel 4
Return parameters: <NR2>
Header on: :FETCH:POWER:PFACTOR<space><NR2><RMT>
:FETCH:POWER:PFACTOR<space><NR2>,<NR2>,<NR2>,<NR2>
<RMT>
Header off: <NR2><RMT>
<NR2>,<NR2>,<NR2>,<NR2><RMT>
Example: none
FETCh[:SCALar]:POWer:APParent? {<NR1>}
MEASure[:SCALar]:POWer:APParent? {<NR1>}
Type: Channel-Specific.
Description: These queries return the apparent power. The return could be -3 or
<NR2>.
-3: Invalid data when OVR、OCR、OCP occur.
Setting syntax: none
Setting parameters: none
Query syntax: FETCh:POWer:APParent?<PMT>,
FETCh:POWer:APParent?<space><NR1><PMT>,
MEASure:POWer:APParent?<PMT>,
MEASure:POWer:APParent?<space><NR1><PMT>
Query parameters: <NR1>, 0 ~ 4, 0:All channel, 1~4:Channel 1 ~ Channel 4
Return parameters: <NR2>
Header on: :FETCH:POWER:APPARENT<space><NR2><RMT>
:FETCH:POWER:APPARENT<space><NR2>,<NR2>,<NR2>,<NR2
><RMT>
Header off: <NR2><RMT>
<NR2>,<NR2>,<NR2>,<NR2><RMT>
Example: none
FETCh[:SCALar]:POWer:REACtive? {<NR1>}
MEASure[:SCALar]:POWer:REACtive? {<NR1>}
Type: Channel-Specific.
Description: These queries return the reactive power. The return could be -3 or
<NR2>.
-3: Invalid data when OVR、OCR、OCP occur.
Setting syntax: none
Setting parameters: none
Query syntax: FETCh:POWer:REACtive?<PMT>,