EasyManua.ls Logo

Chroma 66204 - Page 99

Default Icon
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using Remote Control
5-23
Header on: :FETCH:CURRENT:CRESTFACTOR<space><NR2><RMT>
:FETCH:CURRENT:CRESTFACTOR<space><NR2>,<NR2>,<NR2
>,<NR2><RMT>
Header off: <NR2><RMT>
<NR2>,<NR2>,<NR2>,<NR2><RMT>
Example: none
FETCh[:SCALar]:CURRent:THD? {<NR1>}
MEASure[:SCALar]:CURRent:THD? {<NR1>}
Type: Channel-Specific.
Description: These queries return the total harmonic distortion of current. The
return could be -3 or <NR2>. -3: Invalid data when OCROCP
occur.
Setting syntax: none
Setting parameters: none
Query syntax: FETCh:CURRent:THD?<PMT>,
FETCh:CURRent:THD?<space><NR1><PMT>,
MEASure:CURRent:THD?<PMT>,
MEASure:CURRent:THD?<space><NR1><PMT>
Query parameters: <NR1>, 0 ~ 4, 0:All channel, 1~4:Channel 1 ~ Channel 4
Return parameters: <NR2>
Header on: :FETCH:CURRENT:THD<space><NR2><RMT>
:FETCH:CURRENT:THD<space><NR2>,<NR2>,<NR2>,<NR2><R
MT>
Header off: <NR2><RMT>
<NR2>,<NR2>,<NR2>,<NR2><RMT>
Example: none
FETCh[:SCALar]:POWer:REAL? {<NR1>}
MEASure[:SCALar]:POWer:REAL? {<NR1>}
Type: Channel-Specific.
Description: These queries return the true power. The return could be -1, -2, -3
and <NR2>. -1: The first time integrated calculation is not complete
yet.
-2: RCE represents “range change error” when integration process
is executing.
-3: Invalid data when OVROCROCP occur.
Setting syntax: none
Setting parameters: none
Query syntax: FETCh:POWer:REAL?<PMT>,
FETCh:POWer:REAL?<space><NR1><PMT>,
MEASure:POWer:REAL?<PMT>,
MEASure:POWer:REAL?<space><NR1><PMT>
Query parameters: <NR1>, 0 ~ 4, 0:All channel, 1~4:Channel 1 ~ Channel 4
Return parameters: <NR2>
Header on: :FETCH:POWER:REAL<space><NR2><RMT>
:FETCH:POWER:REAL<space><NR2>,<NR2>,<NR2>,<NR2><RM
T>
Header off: <NR2><RMT>
<NR2>,<NR2>,<NR2>,<NR2><RMT>
Example: none