Questions and Answers

  • R
    Ryan MurphyAug 14, 2025
    How to fix output current over high (general) on Chroma Test Equipment?
    • C
      Chase EllisAug 14, 2025
      If your Chroma Test Equipment shows an output current that is generally too high, try widening the I LIMIT setting.
  • R
    Robert McculloughAug 17, 2025
    How to fix DC Bus voltage over high on Chroma 69225-100-4?
    • C
      Carly WareAug 18, 2025
      If you are experiencing issues with high DC Bus voltage on your Chroma Test Equipment, make sure to calibrate it periodically and observe if the 691101 action is normal.
  • P
    petersonginaAug 21, 2025
    What to do if DC Bus voltage is over low on Chroma 69225-100-4 Test Equipment?
    • J
      Jessica WongAug 21, 2025
      To resolve a low DC Bus voltage issue with your Chroma Test Equipment, calibration periodically is need. Additionally, observe if the 691101 action is normal.
  • B
    Bryan KimAug 25, 2025
    What to do if local voltage is over high on Chroma 69225-100-4?
    • S
      Sarah PrattAug 25, 2025
      If your Chroma Test Equipment shows a high local voltage, check if the output terminal wiring is loosened and verify that the BMS is operating normally.
  • T
    tommy79Aug 28, 2025
    What to do if output current transient is extremely high (fast) on Chroma Test Equipment?
    • S
      scott88Aug 28, 2025
      If your Chroma Test Equipment displays an extremely high transient output current, check if the output terminal wiring is loose and ensure the BMS is operating normally.
  • K
    Kyle AndersonAug 31, 2025
    What to do if local connected reversely on Chroma 69225-100-4?
    • C
      Courtney AlexanderAug 31, 2025
      If your Chroma Test Equipment indicates the local connection is reversed, check to ensure the output terminal connects to the positive/negative terminal exactly.
  • R
    rbishopSep 3, 2025
    What to do if RMT connected reversely on Chroma 69225-100-4 Test Equipment?
    • S
      Steven JacksonSep 3, 2025
      If your Chroma Test Equipment reports that the remote (RMT) connection is reversed, check if the sensor wire connects to the positive/negative terminal correctly.
  • D
    Darin McleanSep 7, 2025
    How to fix wire loss too large (or RMT wire off) on Chroma 69225-100-4 Test Equipment?
    • M
      michelle14Sep 7, 2025
      If your Chroma Test Equipment shows excessive wire loss, check the output wire path for any abnormal or high impedance objects. Also, verify that the output and RMT wires are not loose and fix them if necessary.
  • S
    Spencer KhanSep 10, 2025
    How to prevent 692 inner over-temperature on Chroma 69225-100-4 Test Equipment?
    • D
      Dr. Richard NguyenSep 10, 2025
      The Chroma Test Equipment should be operated under ambient temperature 0°C~ 40°C.

Summary

Warranty

Safety Summary

Safety Symbols

Overview

System Function

Details the operational modes and protection functions of the tester.

Specification

Installation

Preparation for Use

Outlines essential preparation steps before operating the instrument.

Input Power Requirement

Details the voltage, frequency, current, and power requirements.

Connecting the Output

Guides on connecting output terminals for charging/discharging.

Manual;Remote Operation

Parallel Operation

Troubleshooting

Overview

Introduces the troubleshooting procedures for operational issues.

Troubleshooting

Lists common failure causes and their corresponding resolutions.

Chroma 69225-100-4 Specifications

General IconGeneral
BrandChroma
Model69225-100-4
CategoryTest Equipment
LanguageEnglish