Items Specification Standards
Op. Temp
-10
60
-
St. Temp
-25
80
-
Op. Hum
5
95% RH, Not condensed
-
St. Hum
5
95% RH, Not condensed
-
Vibration
In case of Intermittent Vibration
IEC 61131-2
Frequency
Acceleration
Amplitude
Sweep
5 ≤ f < 9 Hz
-
3.5 mm
10 times
in X, Y, Z
9 ≤ f ≤ 150 Hz
9.8 m/s
2
(1G)
-
In case of Continuous Vibration
Frequency
Acceleration
Amplitude
Sweep
5 ≤ f < 9 Hz
-
1.75 mm
10 times
in X, Y, Z
9 ≤ f ≤ 150 Hz
4.9 m/s
2
(0.5G)
-
Shock
Max. shock Acc.: 147 m/s
2
(15G)
Time: 11 ms
Pulse wave: Half sine wave pulse (3 times in X, Y, Z)
IEC 61131-2
Noise
Square Wave
Impulse Noise
±2 kV
CIMON
Standard
Electrostatic
Discharge
±4 kV (Contact), ±8 kV (Air)
IEC 61131-2
IEC 61000-4-2
Radiated
Electromagnetic
Field
80
1000 MHz,10 V/m
IEC 61131-2
IEC 61000-4-3
Fast Transient
Burst Noise
(Voltage)
CPU, Power
2kV
IEC 61131-2
IEC 61000-4-4
Digital/Analog I/O (AC)
Digital/Analog I/O (DC)
1kV
Communication
Ambient
Conditions
No corrosive gas and no dust
Altitude 2,000m or less
Pollution Pollution Degree 2 or less
Cooling
Natural Air Cooling
General Specifications