9-21
EM-573 (N-04-18)
16. Note any machine problems that might require additional attention. Contact CINCINNATI Laser Service for
assistance in resolving those problems.
ANNUAL MACHINE INSPECTION
Complete these steps after each year or 6000 hours, whichever comes rst.
1. Replace the bulbs in the laser status indicators on top of the laser generating unit and the safety enclosure
or as needed.
2. Replace assist gas lter cartridges (C.I. P/N #924856).
3. On the air dryer system, check the differential pressure indicator on the rst stage coalescing lter (Item 2
in Figure 9-9). If the indicator is approaching the red zone or annually (whichever occurs rst), change the
cartridge in the pre-lters and the carbon lter (Item 1,2,3 and 6 in Figure 9-13). A lter kit that includes all
of these cartridges is available as (C.I. P/N #923068).
4. On the air dryer system, check the moisture indicator (Item 8 in Figure 9-13). It should turn green within
30 minutes of turning on the dryer. If it does not turn green, change the moisture indicator cartridge with
C.I. P/N #923067. If the new cartridge still does not turn green, contact CINCINNATI Laser Service for
assistance.
5. For machines with a light source that was CDA or “Clean Air Dry” purge, replace the oil lter cartridge (C.I.
P/N #917210).

Table of Contents

Other manuals for Cincinnati CL-900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cincinnati CL-900 Series and is the answer not in the manual?

Cincinnati CL-900 Series Specifications

General IconGeneral
BrandCincinnati
ModelCL-900 Series
CategoryMeasuring Instruments
LanguageEnglish