TROUBLESHOOTING
Problem Cause Solution
Low flow Dirty filter Backwash or clean cartridge
Dirty skimmer and
pump strainer
Clean skimmer and pump strainer
Suction air leak Make sure water level is correct through suction
points. Ensure baskets and strainers are free of
debris. Tighten all fittings/unions on the suction
side of the pump, remove and replace
mechanical seal
Closed valve or
blocked line
Make sure water level is correct through suction
points. Ensure baskets and strainers are free of
debris. Tighten all fittings/unions on the suction
side of the pump, remove and replace
mechanical seal
Pump does
not run
Not plugged in Check the socket and power cord
GFCI/or main circuit
breaker tripped
Switch on the breaker. If it is immediately
tripped again,
There is a defect in pump or controls.
Faulty Pump shaft
/motor
Replace the pump/motor assembly.
Pump shaft is locked Check if the pump can be rotated by hand and
remove any blockage
Pump will
not prime
Suction air leak Make sure water level is correct through suction
points. Ensure baskets and strainers are free of
debris. Tighten all fittings/unions on the suction
side of the pump, remove and replace
mechanical seal
No water in the pump Make sure the filter tank is full
Closed valves or
blocked lines
Open all valves in the system, clean skimmer
and pump basket, check pump impeller of
blockage
Motor
overload
cuts out
Motor not connected
properly
Have electrician check wiring
Low incoming voltage Voltage at motors should be no more than 6%
above or below nameplate voltage. Have
electrician check voltage; ensure pump is not
running on an extension cord. Report low
supplier to authorities.
Overload due to
binding in pump or
wrong size impeller
Contact supplier