Rev Z Page 1 11/28/2011
Copyright © 2011 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced without the express
written permission of Cirus Controls LLC for each reproduction.
SpreadSmart Rx
TM
(with Touch Screen)
Operation Manual

Table of Contents

Questions and Answers

  • P
    Pamela WalshSep 7, 2025
    Why cannot upload calibration data from PC to SpreadSmart Rx on Cirus Controls Spreader?
    • K
      Kimberly EdwardsSep 7, 2025
      If you cannot upload calibration data from your PC to the SpreadSmart Rx on your Cirus Controls Spreader, here’s what to check: * Bad connection between PC and SpreadSmart Rx: Validate cable connections between the systems. * Data file not selected: Select the data file you wish to upload before pressing “send calibration” on “sprdutil.exe”.
  • T
    Thomas MclaughlinAug 22, 2025
    What to do if SS Rx display goes blank and functions stop on Cirus Controls SpreadSmart Rx?
    • B
      Billy AndersonAug 22, 2025
      If the display of your Cirus Controls Spreader goes blank and functions cease on a system that previously worked, it likely indicates a shorted or open circuit externally, often involving a sensor or a damaged cable connection. To troubleshoot: * Disconnect the Hyd Out, Sensor In, and Anti-ice Booms. * If the display comes back on, one of these components has an open/short. * Reconnect the cables one at a time to identify the damaged component. * Replace the damaged component.
  • A
    Anthony ConleySep 4, 2025
    Why flow rate won’t calibrate on Cirus Controls SpreadSmart Rx Spreader?
    • P
      Philip RobertsonSep 5, 2025
      If your Cirus Controls Spreader's flow rate won’t calibrate, consider the following: * Flow meter inaccurate (meter, sensor or cable): Use test mode to compare pulses to the volume of liquid flowing. Replace the meter or sensor if needed. * Units conversion error: The SS Rx must be set in the desired units (English or metric) before any setup occurs. Re-start the complete setup procedure with units set correctly.
  • J
    Jordan MorganSep 3, 2025
    Why auger/spinner move, but output rates not indicated on Cirus Controls SpreadSmart Rx?
    • K
      kallenSep 3, 2025
      If the auger/spinner on your Cirus Controls Spreader move, but output rates are not indicated, consider these potential issues: * Auger sensor failure: Check the sensor wiring and the sensor itself. * Sensor flashes, but signal not displayed in Test mode: Check the sensor signal cable and verify that the spreader setup shows “sensor present”.
  • N
    Nancy NormanSep 2, 2025
    Why I'm unable to maintain steady application at set rate (low speed) on Cirus Controls Spreader?
    • T
      Todd MarshallSep 2, 2025
      If you are unable to maintain a steady application rate at low speed with your Cirus Controls Spreader, consider the following: * The auger is not trimmed properly for low-speed operation: Re-trim the hydraulic system to improve low-speed performance. * Advanced settings need adjustment (sticky valves): Adjust parameters – this should be done by a qualified technician only.
  • K
    Kimberly MartinezAug 31, 2025
    How to fix power if it isn’t on Cirus Controls SpreadSmart Rx Spreader?
    • M
      Michelle JonesAug 31, 2025
      If the Cirus Controls Spreader isn’t turning on, check the following: * Master Power: Ensure the truck is turned on. * Fuse: Replace any blown fuse(s). * Power/Ground Connections: Verify the power and ground connections.
  • K
    Katie CampbellAug 30, 2025
    Why SpreadSmart Rx cuts out or acts strange on Cirus Controls Spreader?
    • D
      Deborah BurnsAug 30, 2025
      If the SpreadSmart Rx on your Cirus Controls Spreader cuts out or acts strangely, it might be due to low power supply voltage from the truck battery/alternator. Ensure the minimum truck voltage is above 12.0 volts.
  • J
    Julie AndersonAug 28, 2025
    What causes speedometer alarm on Cirus Controls SpreadSmart Rx?
    • J
      Judy BrownAug 29, 2025
      If your Cirus Controls Spreader's speedometer alarm is triggered, it could be due to: * Speedometer signal lost: Verify cable connections. * Speedometer not calibrated: Follow the Speedo set up steps.
  • M
    msimmonsAug 27, 2025
    Why settings on display are shown in % (not in lbs/mile) on Cirus Controls SpreadSmart Rx?
    • I
      Isabella RodriguezAug 27, 2025
      If your Cirus Controls Spreader's settings are displayed in percentage (%) instead of pounds per mile (lbs/mile), here's what might be happening: * Automatic mode: The system is not set up and trimmed properly. Follow the Set Up and Trim procedure. * Manual mode is selected: Select Automatic mode.
  • K
    kathrynharrellAug 27, 2025
    What to do if pre-wet or anti-ice alarm sounds/flash on Cirus Controls SpreadSmart Rx?
    • J
      joshua67Aug 27, 2025
      If you're getting a pre-wet or anti-ice alarm (sound/flash) on your Cirus Controls Spreader, here are the possible causes and solutions: * Pre-Wet Pump Stopped: Repair the pump or clear any obstructions. * Pre-Wet Sensor Failure: Repair the sensor or cable. * Minimum trim too low: Adjust the minimum trim. * Stuck or sticky valve: Adjust the “coil unseat” settings; repair valve coil.

Cirus Controls SpreadSmart Rx Specifications

General IconGeneral
Data LoggingYes
DisplayLCD
Material CompatibilitySalt
Power Source12V DC
CompatibilityVarious spreaders