Questions and Answers

  • K
    katherine63Aug 25, 2025
    What causes auger alarm sound/flash on Cirus Controls Spreader?
    • J
      jennifer94Aug 26, 2025
      If you're experiencing an auger alarm (sound/flash) on your Cirus Controls Spreader, it could be due to several reasons: * The auger has stopped: Clear any jams. * Auger sensor failure: Repair the sensor or cable. * Minimum trim too low: Adjust the minimum trim. * Stuck or sticky valve: Adjust the “coil unseat” settings or repair the valve coil.
  • S
    Shannon Snyder MDAug 23, 2025
    Why auger or spinner doesn’t move on Cirus Controls SpreadSmart Rx Spreader?
    • V
      Victor WilliamsAug 23, 2025
      If the auger or spinner on your Cirus Controls Spreader isn't moving, here's what you should check: 1. Engage the PTO. 2. Verify the hydraulics by actuating the plow or hoist, or manually operate them using the manual override on the valve. 3. Check the LED at the coil connection and at the valve junction box, and repair the cable if needed. 4. Check the wiring connections.