Total: 8 GB
Allocated to FW/VPN: 4 GB
Allocated to Module: 4 GB
DRAM
8 GBInternal Flash
60 WPower
Environment
Operating: 0°C to 40°C (32°F to 104°F)
Nonoperating: -25°C to 70°C (-13°F to 158°F)
Temperature
Operating: 90%
Nonoperating: 10% to 90%
Relative humidity
Operating: 3048 m (10,000 ft)
Nonoperating: 4572 m (15,000 ft)
Maximum altitude
Typical: 41.6 dBA
Maximum: 67.2 dBA
Acoustic Noise
Power Cord Specifications
Each power supply has a separate power cord. Standard power cords are available for connection to the security
appliance.
If you do not order the optional power cord with the system, you are responsible for selecting the appropriate
power cord for the product. Using a non-compatible power cord with this product may result in electrical
safety hazard. Orders delivered to Argentina, Brazil, and Japan must have the appropriate power cord ordered
with the system.
Only the approved power cords provided with the security appliance are supported. The following table lists
the supported power cords.
Table 2: Supported Power Cords
ConnectorPlugVoltageAmperageDescription
IEC 60320/C13CEE 7 VII250V10ACAB-ACE
AC power cord
(Europe)
Cisco ASA 5508-X and ASA 5516-X Hardware Installation Guide