EasyManuals Logo

Cisco ASR 903 Troubleshooting

Cisco ASR 903
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
DB-9 Connector Pinouts
The table below summarizes the pinouts for each serial interface type when using a DB-9 connector.
Table 11: DB-9 Pin-outs
IRIG-BRS-485DescriptionDirectionStandard DB-9Pin
NCNCUnusedOutputNC1
NCNCReceiveInputRxD2
IRIG-B (RS232)IRIG-B (RS232)TransmitOutputTxD3
IRIG-B-
(RS485)
TxD-DTROutputDTR4
GNDGNDGNDGND5
NCRxDDSRInputDSR6
IRIG-B+TxD+RTSOutputRTS7
NCRxD+ (CTSInputCTS8
NCNCUnused or RingNC/GND9
Twisted pairs are 2-5, 6-8, 4-7.Note
The X.21, V.35, RS-485, EIA-449, EIA-530, and IRIG-B standards are not currently supported by software.Note
RJ-45 Connector Pinouts
The table below summarizes the pinouts for each serial interface type when using an RJ-45 connector.
Table 12: RJ45 Pinout
IRIG-BRS-485DescriptionDirectionStandard DB-9Pin
NCRxD+ (RS485)Ready to sendInputRTS1
NCRxD- (RS485)DTRInputDTR2
NCNCTransmitInputTxD3
Cisco ASR 903 Aggregation Services Router Hardware Installation Guide
12
Troubleshooting
DB-9 Connector Pinouts

Other manuals for Cisco ASR 903

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 903 and is the answer not in the manual?

Cisco ASR 903 Specifications

General IconGeneral
Form FactorModular
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% non-condensing
RedundancyYes, redundant power supplies and route processors
Operating SystemCisco IOS XE
Power SupplyAC or DC
Switching Capacity240 Gbps
Operating Temperature-40°C to 65°C (-40°F to 149°F)
MTBF200, 000 hours
Supported ProtocolsIPv4, IPv6, MPLS, L2VPN, L3VPN
InterfacesGigabit Ethernet, 10 Gigabit Ethernet, T1/E1