SpecificationEnvironmental
C6840-X-LE-40GC6824-X-LE-40GC6832-X-LEC6816-X-LE
Certified for operation: 0 to 6500 ft (0 to 2000 m)
Designed and tested for operation: -200 to 10,000 ft (-60 to 3000 m)
Altitude,
operating
Shock
• Operational - 5 G 30 ms, half-sine (IEC 68-2-27)
• Nonoperational - 20 G, 7.5 ms, trapezoidal
Vibration
• Operational - 3 Hz to 500 Hz
• Power Spectral Density (PSD) - 0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll
off at each end. 0.5 hours per axis (1.12 Grams).
Shock and
vibration
Sound power level, 67 dB@27°CAcoustic
noise
Physical characteristics
• Height = 3.47 inches (8.81 cm)
• Width = 17.35 inches (44.07 cm)
• Depth = 21.8 inches (55.38 cm)
• Rack Units (RU) = 2 RU
Dimensions
37.03 lbs/16.8 kgs34.83 lbs/15.8 kgs33.95 lbs/15.4 kgs
24.04 lbs/10.09
kgs
Weight
Chassis with
2 power
supplies and a
built-in fan
C6840-X-FAN
The airflow in the Catalyst 6840-X switch chassis is from front to back. See Site
Requirements, on page 21 for recommended separations between walls and the
chassis air intake and air exhaust and between the air exhaust of one chassis with
the air intake of another chassis. Failure to maintain adequate air space can cause
the chassis to overheat and the system to fail.
Note
Airflow
Catalyst 6840-X Switch Series Hardware Installation Guide
66
Technical Specifications
Technical Specifications