Revised: October 8, 2018
Maintaining the Power System in the Cisco cBR Chassis
Removing the AC Power Connections from the Cisco cBR Chassis
The chassis ground connection must always be made first and disconnected last.
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030
Warning
Before you begin
Required Tools and Equipment
#2 Phillips screwdriver
Procedure
Step 1 Power down the AC FPEM using the power switch.
Step 2 Power down the AC circuit or power source to which the AC power cord is connected.
Step 3 Loosen the Phillips-head screw on the cable retaining bracket using a #2 Phillips screwdriver.
Step 4 Unplug the AC power cord from the receptacle on the AC FPEM.
Figure 1: Removing AC Power Cord from the AC FPEM
AC power cord2Screw on the cable retaining bracket1
Step 5 Repeat Step 2, on page 2 to Step 4, on page 2 for each AC power connection.
2

Other manuals for Cisco cBR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco cBR Series and is the answer not in the manual?

Cisco cBR Series Specifications

General IconGeneral
CategoryNetwork Router
Modular DesignYes
Operating SystemCisco IOS XE
Model ExamplescBR-8, cBR-4
Product SeriescBR Series
PurposeConverged Broadband Router
DOCSIS SupportDOCSIS 3.1
RedundancyYes
ManagementCisco Prime
Product FamilycBR Series
Downstream Frequency RangeUp to 1.2 GHz
Upstream Frequency RangeUp to 204 MHz
Modulation SchemesQAM
Power SupplyRedundant AC or DC power supplies
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Humidity5 to 95% noncondensing