e) Install the second inner rail to the opposite side of the chassis and secure with the other M3X6mm screw.
Step 3
Open the front securing plate on both slide-rail assemblies. The front end of the slide-rail assembly has a spring-loaded
securing plate that must be open before you can insert the mounting pegs into the rack-post holes.
On the outside of the assembly, push the green arrow button toward the rear to open the securing plate.
Figure 17: Front Securing Mechanism Inside the Front End
Securing plate shown pulled back to open
position
2Front mounting pegs
Works with square slots,
7.1mm holes, and 10-32
threaded holes.
Note
1
Rack post3
Step 4
Install the slide rails into the rack:
a) Align one slide-rail assembly front end with the front rack-post holes that you want to use.
The slide rail front-end wraps around the outside of the rack post and the mounting pegs enter the rack-post holes
from the outside-front.
The rack post must be between the mounting pegs and the open securing
plate.
Note
b) Push the mounting pegs into the rack-post holes from the outside-front.
c) Press the securing plate release button marked 'PUSH.' The spring-loaded securing plate closes to lock the pegs in
place.
d) Adjust the slide-rail length, and then push the rear mounting pegs into the corresponding rear rack-post holes. The
slide rail must be level front-to-rear.
The rear mounting pegs enter the rear rack-post holes from the inside of the rack post.
e) Attach the second slide-rail assembly to the opposite side of the rack. Make sure that the two slide-rail assemblies
are at the same height with each other and are level front-to-back.
f) Pull the inner slide rails on each assembly out toward the rack front until they hit the internal stops and lock in place.
Step 5
Insert the chassis into the slide rails.
Cisco Firepower 2100 Series Hardware Installation Guide
37
Mount and Connect
Rack-Mount the Chassis

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Firepower 2120 and is the answer not in the manual?

Cisco Firepower 2120 Specifications

General IconGeneral
Form Factor1RU
Memory16 GB
Operating Temperature32 to 104°F (0 to 40°C)
Maximum Concurrent Sessions2, 000, 000
Maximum Connections2 million
Management Ports1 x 1G management port
Storage480 GB SSD
Power SupplyDual, hot-swappable power supplies
Interfaces8 x 1GE, 8 x 1GE SFP

Related product manuals