EasyManua.ls Logo

Cisco IE-4000-16GT4G-E - Page 33

Cisco IE-4000-16GT4G-E
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-15
Cisco IE 4000 Switch Hardware Installation Guide
Chapter 2 Switch Installation
Connecting to Power
Figure 2-6 Inserting Wires in the Power Connector
Step 7 Use a ratcheting torque flathead screwdriver to torque the power connector captive screws (above the
installed wire leads) to 5in-lb (0.565 Nm). See Figure 2-7.
Caution Do not over-torque the power connectors captive screws. The torque should not exceed 5in-lb (0.565
Nm).
1 Power source positive connection 2 Power source return connection
332021
1 2