MEA on fan tray—No5A15454E-SA-ETSI
MEA on fan tray and 10G cards—Yes5A15454E-SA-ETSI
None—No5A15454E-SA-ETSI
MEA on 10G—Yes5A15454E-SA-ETSI
None—No2AETSI
MEA on fan tray or Ethernet2.5G compatibleYes2AETSI
MEA on fan tray10G compatibleYes2AETSI
NoneEitherNo2AETSI
MEA on fan tray, Ethernet2.5G compatibleYes2AETSI
MEA on fan tray10G compatibleYes2AETSI
MEA on Ethernet2.5G compatibleYes5AETSI
NoneEitherNo5AETSI
NoneEitherYes5AETSI
6
15454-SA-ETSI (P/N: 800-08708-XX) = ONS 15454 SDH Release 3.3 and later shelf assembly
7
5A Fan Tray = 15454E-FTA-60V, 15454E-CC-FTA2A Fan Tray = 15454E-FTA-48V
8
10G cards = XC10G, XC-VXL-10G, XC-VXC-10G
Step 2 Open the front door of the shelf assembly. If the shelf assembly does not have a front door, continue with
Step 4.
a) Open the front door lock.
The ONS 15454 comes with a pinned hex key for locking and unlocking the front door. Turn the key
counterclockwise to unlock the door and clockwise to lock it.
b) Press the door button to release the latch.
c) Swing the door open.
Step 3 (Optional) Complete the DLP-G577 Remove the Standard Door of the ONS 15454 M6 Shelf to remove the
front door. If you do not want to remove the door, proceed to Step 4.
Step 4 Push the outer side of the handles on the fan-tray assembly to expose the handles.
Step 5 Fold out the retractable handles at the outside edges of the fan tray.
Step 6 Pull the handles and slide the fan-tray assembly one inch (25.4 mm) out of the shelf assembly and wait until
the fans stop.
Step 7 When the fans have stopped, pull the fan-tray assembly completely out of the shelf assembly. The following
figure shows the location of the fan tray on the ONS 15454 ANSI shelf.
Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf
19
Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf
NTP-G116 Replace the Fan-Tray Assembly of the ONS 15454 Shelf Assembly