Status and Statistics
Health and Power
Cisco Sx350, SG350X, SG350XG, Sx550X & SG550XG Series Managed Switches, Firmware Release 2.2.5.x 48
4
PoE—The Port Management > PoE > Settings page is displayed. Connect the time
range to the PoE operations on one or more ports.
If the device is not part of a stack, the Health and Power page displays the following
fields:
Health Table
Fan Status—The following values are possible:
- OK—Fan is operating normally.
- Failure—More than one fan is not operating correctly.
- N/A—Fan is not applicable for the specific model.
Redundant Fan Status—The following values are possible:
- Ready—Redundant fan is operational but not required.
- Active—One of the main fans is not working and this fan is replacing it.
Temperature—The options are:
- OK—The temperature is below the warning threshold.
- Warning—The temperature is between the warning threshold to the critical
threshold.
- Critical—Temperature is above the critical threshold.
- N/A—Not relevant.
Main Power Status (these fields are found on device that are PD devices and in
devices that support RPS)
- Main Power Supply Status—Displays one of the following for the main power
supply:
Active—Power supply is being used.
Failure—Main power has failed.
- Main Power Supply Budget—Amount of power that can be can be allocated for
device PSE operation by the main power supply.