Administration Settings
Management
Cisco SPA100Series Administration Guide 108
5
Cisco SPA122 Web Access fields
Cisco SPA122 Remote Access fields
Field Description
Admin Access This feature controls access to the configuration utility
from devices that are connected via the ETHERNET
(LAN) port.
Click Enabled to enable this feature, or click Disabled to
disable it. The default setting is Enabled. If you
administer and configure the ATA from a computer that
is connected to the LAN, this feature must be enabled.
Web Utility Access Select the protocol to use for access to the
configuration utility from a device on the WAN. Choose
HTTP and/or HTTPS. For secure Internet access, select
HTTPS. The default value is HTTP.
Field Description
Remote
Management
Allows access to the configuration utility from a device
that is on the WAN side of the ATA. For example, you
could connect from another subnet in your office or from
your home computer.
Click Enabled to enable this feature, or click Disabled to
disable it. The default setting is Disabled. The other
fields in this section of the page are available only if you
enable this feature.
If you attempt to enable this feature while using the
default administrator login credentials, you will be
prompted to change the credentials. Click OK to
acknowledge the warning message. Use the
Administration > Management > User List page to
change administrator password. For more information,
see User List (Password Management), page 113.

Table of Contents

Other manuals for Cisco SPA112

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SPA112 and is the answer not in the manual?

Cisco SPA112 Specifications

General IconGeneral
Supported network protocolsIPv4, IPv6, ARP, DNS, SRV, DHCP, PPPoE, ICMP, TCP, UDP, RTP, RTCP, SNTP
DHCP clientYes
VPN support802.1p
Security algorithmsSSL/TLS
Authentication methodSIP
Modem (RJ-11) ports2
Ethernet LAN (RJ-45) ports1
Voice codecsG.711, G.726, G.729
CertificationFCC, CE, ICES, A-Tick, RoHS, UL
Fax compatibilityT.38
Output current2 A
Output voltage5 V
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Storage temperature (T-T)-25 - 70 °C
Operating temperature (T-T)0 - 45 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Width101 mm
Height28 mm
Weight153 g