Configuring the Voice Settings
Line1 and Line 2 Settings (PHONE Port1 and PHONE2)
Cisco SPA100Series Administration Guide 90
4
Proxy and Registration
Emergency
Number
Comma separated list of emergency number patterns. If
outbound call matches one of the pattern, the ATA will
disable hook flash event handling. The condition is
restored to normal after the call ends. Blank signifies that
there is no emergency number. Maximum number length is
63 characters.
Default setting: blank
Mailbox ID Enter the ID number of the mailbox for this line.
Default setting: blank
Field Description
Proxy SIP proxy server for all outbound requests.
Default setting: blank
Outbound Proxy SIP Outbound Proxy Server where all outbound requests
are sent as the first hop.
Default setting: blank
Use Outbound
Proxy
Enables the use of an Outbound Proxy. If set to no, the
Outbound Proxy and Use OB Proxy in Dialog parameters
are ignored.
Default setting: no
Use OB Proxy In
Dialog
Whether to force SIP requests to be sent to the outbound
proxy within a dialog. Ignored if the parameter Use
Outbound Proxy is no, or the Outbound Proxy parameter is
empty.
Default setting: yes
Register Enable periodic registration with the Proxy parameter. This
parameter is ignored if Proxy is not specified.
Default setting: yes
Make Call Without
Reg
Allow making outbound calls without successful (dynamic)
registration by the unit. If No, dial tone will not play unless
registration is successful.
Default setting: no
Field Description

Table of Contents

Other manuals for Cisco SPA112

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SPA112 and is the answer not in the manual?

Cisco SPA112 Specifications

General IconGeneral
Supported network protocolsIPv4, IPv6, ARP, DNS, SRV, DHCP, PPPoE, ICMP, TCP, UDP, RTP, RTCP, SNTP
DHCP clientYes
VPN support802.1p
Security algorithmsSSL/TLS
Authentication methodSIP
Modem (RJ-11) ports2
Ethernet LAN (RJ-45) ports1
Voice codecsG.711, G.726, G.729
CertificationFCC, CE, ICES, A-Tick, RoHS, UL
Fax compatibilityT.38
Output current2 A
Output voltage5 V
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Storage temperature (T-T)-25 - 70 °C
Operating temperature (T-T)0 - 45 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Width101 mm
Height28 mm
Weight153 g