EasyManuals Logo

Cisco UCS 5108 User Manual

Cisco UCS 5108
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
7 © 2014 Cisco and/or its affiliates. All rights reserved.
UCSM Non-Standalone I/O Throttle Count Configuration
The I/O Throttle Count for non-standalone servers is configured through the UCSM GUI or equivalent UCSM XML commands.
The I/O Throttle Count parameter is configurable in the Linux and VMWare FC Adapter Policies.
To change the I/O Throttle Count parameter, in the UCSM navigation tree, click the Servers tab, then expand the Policies and
Adapter Policies in the navigation tree. Click the FC Adapter Policy Linux or FC Adapter Policy VMWare, and then, in the main
window, expand the Options drop-down. Configure the I/O Throttle Count field per the list of parameter values above, and then
click the Save Changes button.

Other manuals for Cisco UCS 5108

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS 5108 and is the answer not in the manual?

Cisco UCS 5108 Specifications

General IconGeneral
Number of Blade Slots8
I/O Module Bays2
Supported Blade ServersCisco UCS B-Series Blade Servers
Power Supply OptionsUp to four hot-swappable power supplies (AC or DC)
CoolingRedundant hot-swappable fans
ManagementCisco UCS Manager
Blade Slots8
Fabric InterconnectsCisco UCS 6100 or 6200 Series
Power SuppliesUp to 4 hot-pluggable power supplies
Form Factor6RU rack-mountable