EasyManua.ls Logo

Citizen iDP3550 - Input and Output Signals

Citizen iDP3550
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iDP3550/3551 User’s Manual
29
CITIZEN
9.3 Input and Output Signals
9.3.1 Input and Output Signals
(1) Input signals to the printer
• DATA : An 8-bit parallel signal. (Active “High”)
• STB : A strobe signal to read the 8-bit data. (Active “Low”)
• RESET : A signal to reset the printer from the outside. (Active “Low”)
(2) Output signals from the printer
• ACK : An 8-bit data request signal. A pulse signal output at the end of the BUSY signal.
(Active “Low”)
• BUSY :A signal to indicate the BUSY status of the printer. Input new data when at "Low".
(Active “High”)
• FAULT : A signal turned to "Low" when the printer has an alarm. At this time, all the
control circuits in the printer stop. (Active “Low”)
• SELECT : A signal to show whether the printer is selected (On-line) or deselected.
(Active “High”)
•COMPULSION
: A signal to show the status of the drawer switch. ( Active “High”)
• PE : A signal to show that the paper has run out. Normal at the "Low" level, but turned
to the "High" level when the paper has run out.
(3) Power related signal
• GND : Common ground on the circuits
• Vcc : A +5 V signal. Connected via a 3.3kΩ resistor. (Factory use only)