• Switching or disconnecting devices must not be in the earthed circuit conductor between the
DC source and the point of connection of the earthing electrode conductor.
Statement 6:
Caution: To reduce the risk of electric shock or energy hazards:
• This equipment must be installed by trained service personnel in a restricted‑access location,
as defined by the NEC and IEC/UL/CSA 60950‑1 and 62368‑1, the Standard for Safety of IT Equip‑
ment.
• Connect the equipment to a properly grounded safety extra low voltage (SELV) source. A SELV
source is a secondary circuit that is designed so that normal and single fault conditions do not
cause the voltages to exceed a safe level (60 V direct current).
• Incorporate a readily available approved and rated disconnect device in the field wiring.
• See the specifications in the product documentation for the required circuit‑breaker rating for
branch circuit overcurrent protection.
• Use copper wire conductors only. See the specifications in the product documentation for the
required wire size.
• See the specifications in the product documentation for the required torque values for the
wiring‑terminal nuts.
Statement 7:
Caution: Shock hazard. Equipment might be powered by multiple sources.
Statement 8:
Caution: During installation or maintenance procedures, wear a grounding wrist strap to avoid ESD
damage to the electronics of the appliance. Use a conductive wrist strap attached to a good earth
ground or to the appliance. You can attach it to the connector beside the ESD symbol on the back.
Statement 9:
Warning: Hazardous moving parts. Keep away from moving fan blades.