Citrix ADC MPX
Health
attribute Unit
Lower
Non‑
Recoverable
Lower
Critical
Lower
Non‑
Critical
Upper
Non‑
Critical
Upper
Critical
Upper
Non‑
Recoverable
VTT Volts 0.816 0.864 0.912 1.344 1.392 1.440
CPU1
Vcore
Volts 0.480 0.512 0.544 1.488 1.520 1.552
CPU2
Vcore
Volts 0.480 0.512 0.544 1.488 1.520 1.552
VDIMM AB Volts 1.104 1.152 1.200 1.648 1.696 1.744
VDIMM
CD
Volts 1.104 1.152 1.200 1.648 1.696 1.744
VDIMM EF Volts 1.104 1.152 1.200 1.648 1.696 1.744
VDIMM
GH
Volts 1.104 1.152 1.200 1.648 1.696 1.744
+1.5 V Volts 1.248 1.296 1.344 1.648 1.696 1.744
3.3 V Volts 2.640 2.784 2.928 3.648 3.792 3.936
+3.3VSB Volts 2.640 2.784 2.928 3.648 3.792 3.936
5 V Volts 4.096 4.288 4.480 5.504 5.696 6.912
12 V Volts 10.176 10.494 10.812 13.250 13.568 13.886
VBAT Volts 2.400 2.544 2.688 3.312 3.456 3.600
Health attributes for MPX 24100 platform
The following table lists the health attributes for MPX 24100/24150.
Health
attribute Unit
Lower
Non‑
Recoverable
Lower
Critical
Lower
Non‑
Critical
Upper
Non‑
Critical
Upper
Critical
Upper
Non‑
Recoverable
CPU1
Temp
degrees C 0.000 0.000 0.000 90.000 93.000 95.000
CPU2
Temp
degrees C 0.000 0.000 0.000 90.000 93.000 95.000
System
Temp
degrees C ‑9.000 ‑7.000 ‑5.000 80.000 85.000 90.000
© 1999–2023 Cloud Soware Group, Inc. All rights reserved. 199