Specifications
Descriptions
EVD-3500- 08
EVD-3500- 10
EVD-3500-P08
EVD-3500-P10
Analog type Parallel type
Working fluid
Max. working pressure
Min. working pressure (kPa)
Inlet side
Withstanding pressure
Output side
Control pressure range
Power supply voltage
Current consumption
Input signal
(Input impedance)
Preset input
Output signal Note 1
Error output signal
Direct memory setting
Hysteresis Note 2
Linearity Note 2
Resolution Note 2
Repeatability Note 2
Zero point fluctuation
Temperature characteristics
Span point fluctuation
Max. flow rate (ANR) Note 3
Step response time Note 4
Mechanical vibration proof
Ambient temperature
Working fluid temperature
Port size
Installation attitude
Mass
Protective circuit
Clean compressed air
700 kPa
Set pressure+maximum control pressure X 0.2
1050 kPa
750kPa
0 to 500 kPa
24 VDC 10% (stabilized power supply with ripple rate of 1% or less)
0.15 A or less (0.6 A rush current when power turned on)
Analog output: 1-5 VDC (connected load impedance of 500 k and over)
5 to 500 kPa (setting minimum width 1kPa)
0.5% F.S. or less
0.3% F.S. or less
0.2% F.S. or less
0.3% F.S. or less
0.15% F.S./ or less
0.07% F.S./ or less
1500 /min
0.2sec. or less (loadless)
98m/s
2
or less
5 to 50
5 to 50
Rc1/4, Rc3/8
Free
450g
Power supply reverse connection prevention, switch output reverse connection protection, switch output load short-circuit protection
0 to 10 VDC (6.7k )
0 to 5 VDC (10k )
4 to 20 mADC (250 )
8 points
10bit
None
Note 1: Select either analog or switch output.
Note 2: The above applies in control pressure 10 to 90 % with 24 VDC power voltage and working pressure set at the maximum control pressure 1.2 (=0.6 MPa).
Pressure may fluctuate if used for applications such as blowing only when the secondary side is a closed circuit.
Note 3: The above apply when working pressure and control pressure are maximum.
Note 4: The above apply when working pressure is maximum and the step is as follows: 50% F.S. -> 100% F.S.
50% F.S. -> 60% F.S.
50% F.S. -> 40% F.S.
Switch output: NPN or PNP open collector output, 50 mA or less, voltage drop of 2.4 V or less, PLC and relay compatible
NPN or PNP open collector output, 50 mA or less, voltage drop of 2.4 V or less, PLC and relay compatible
Digital electro pneumatic regulator
EVD-3000 Series
5
JIS symbol
A
P
R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CKD EVD Series and is the answer not in the manual?

CKD EVD Series Specifications

General IconGeneral
BrandCKD
ModelEVD Series
CategoryController
LanguageEnglish

Related product manuals