299 216.0 - RHB MEDION 340 - 310 1.5.5
Specifications
Hydrostatic ground drive
Machine type Capacity / Litres Setting pressure bar
New filling Oil change at corresp. pressure relief valve
MEDION 340
Type 934
approx. 25 approx. 20
Operating pressure
◆
420
Charge pressure L4 / L5
18
+1
Cold-start valve
25
+2.5
MEDION 330
Type 932
approx. 25 approx. 20
Operating pressure
◆
420
Charge pressure L4 / L5
18
+1
Cold-start valve
25
+2.5
MEDION 320
Type 932
approx. 25 approx. 20
Operating pressure
◆
420
Charge pressure L4 / L5
18
+1
Cold-start valve
25
+2.5
MEDION 310
Type 932
approx. 25 approx. 20
Operating pressure
◆
420
Charge pressure L4 / L5
18
+1
Cold-start valve
25
+2.5
❋ = Observe circulation pressure when making new settings, i.e. add to the indicated value.
◆ = max. absolute pressure
Hydrostatic ground drives
L4 = LINDE HPV 105 / HMV 105
L5 = LINDE HPV 75 / HMV 105
When selecting the hydraulic oil, the following conditions need to be met:
Pourpoint
Viscosity 0 °C
Viscosity 40 °C
Viscosity index
< -25 °C (DIN ISO 3016)
< 600 cSt. (DIN 51 562)
max. 50.6 cSt. (DIN 51 562)
> 170 (DIN ISO 2909)
The oil must have detergent properties!
The working and the ground drive hydraulics have one common hydraulic oil tank.