Page 19
Manual Regeneration
Sometimes there is a need to regenerate the system sooner than when the
system calls for it, usually referred to as manual regeneration. There may
be a period of heavy water usage because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time, when the regeneration time option is set to “NORMAL” or
“NORMAL + on 0”, press and release “REGEN”. The words “REGEN TODAY” will fl ash on the display to indicate that the system
will regenerate at the preset delayed regeneration time. If you pressed the “REGEN” button in error, pressing the button again
will cancel the request. Note: If the regeneration time option is set to “on 0” there is no set delayed regeneration time so “REGEN
TODAY” will not activate if “REGEN” button is pressed.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled.
Note: For softeners, if the brine tank does not contain salt, fi ll with salt and wait at least two hours before regenerating.
Set Time of Day
The user can also set the time of day. Time of day should only need to be set if the battery has been depleted because of extended
power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will fl ash on and
off which indicates the time of day should be reset. The non rechargeable battery should also be replaced.
STEP 1U
STEP 2U
STEP 3U
RETURN TO NORMAL MODE
STEP 1U – Press SET CLOCK.
STEP 2U - Current Time (hour): Set the hour of the day using or buttons. AM/PM toggles after 12.
Press NEXT to go to Step 3U.
STEP 3U - Current Time (minutes): Set the minutes of the day using or buttons. Press NEXT to
exit Set Time of Day. Press REGEN to return to previous step.
REGEN TODAY will
Flash if a regeneration is
expected “Tonight.”