Filox Series Filter
FILOX WS ISS 2 \page 1
Installation
Operation
Maintenance
Manual
Filox Filter
WS1, WS1.5 & WS2 Series Valve
Models
CF 1054/EN CB 1248/EN
CF1354/EN CF1465/WC
CF1665/WC CF1865/WC
CF 2160/WC CF2469/WC
CF3072/WC

Other manuals for Clack Valves WS2

Questions and Answers

  • S
    Stephanie StevensSep 18, 2025
    Why is the time of day flashing on my Clack Valves WS2?
    • R
      Rose EvansSep 18, 2025
      If the time of day is flashing on and off on your Clack Valves Water System, it's likely due to a power outage. Reset the time of day. If the PC Board has battery back up present the battery may be depleted.
  • A
    Adam GarciaNov 19, 2025
    Why is my Clack Valves Water System delivering hard water?
    • C
      Claudia DavidsonNov 19, 2025
      If you're getting hard or untreated water from your Clack Valves Water System, here's what might be happening: * The bypass valve might be open or faulty. Make sure it's fully closed, or replace it. * High water usage could have exhausted the media. Check your program settings for abnormal water usage. * The meter might not be registering. Remove it and check for rotation or any foreign material. * There might be a fluctuation in water quality. Test the water and adjust the program values accordingly. * The regenerant tank might be empty or have a low level of regenerant. Add the proper regenerant to the tank. * The control might be failing to draw in regenerant. Refer to Trouble Shooting Guide number 12. * There might be an insufficient regenerant level in the regenerant ta...

Summary

3.0 General Notes

3.1 Iron & Manganese Removal

Explains the filter's capability to remove iron and manganese contaminants.

4.0 Regeneration;Backwash

4.1 The Backwash Process

Describes the two-stage process of backwashing the filter media.

5.0 Pre-Installation Checks

5.1.3 Incoming Water

Details the required quality parameters for the incoming raw water supply.

5.2 Electrical

Requirements for the electrical supply, including voltage, fuse, and plug.

6.0 Assembly;Installation

6.2 Assembly

Step-by-step guide for assembling the filter vessel, riser, and valve.

7.0 Commissioning

7.3 Commissioning

Detailed steps for performing the final commissioning of the filter system.

8.0 Routine Monitoring

9.0 Fault Finding and Rectification

9.1 No Flow to Service

Troubleshooting steps for issues related to insufficient or no water flow.

9.2 Poor Treated Water Quality

Diagnosing and resolving problems with the quality of the filtered water.

9.3 No Backwash

Steps to take when the filter's backwash cycle is not initiating or completing.

11.0 Technical Data

Clack Valves WS2 Specifications

General IconGeneral
ModelWS2
TypeControl Valve
Operating Pressure20-125 psi
ApplicationWater Softening
Water Temperature34-110°F
RegenerationDownflow or Upflow