Clarke Focus Boost
Do not put chemicals in the machine!
1)
2)
Open the filler neck (A, Fig.14).
(
For
machines
without
Chemical
Mixing
System
)
Use the front filler neck (B) or the rear filler neck (C) to fill the
tank (D) with a solution suitable for the work to be performed.
Refill to the reference mark “1” of the level check hose (H).
Always follow the dilution instructions on the label of the
chemical product used to prepare the solution.
The solution temperature must not exceed +104°F (+40°C).
WARNING!
Use
only
low-foam
and
non-flammable
detergents,
intended
for
automatic
scrubber
applications.
3)
(
For
machines
with
Chemical
Mixing
System)
Fill the tank (D) with clean water by using the filler neck (B)
or the rear filler neck (C).
Refill to the reference mark “1” of the level check hose (H).
The water temperature must not exceed +104°F (+40°C).
Figure
14
Detergent
tank
filling
(For
machines
with
Chemical
Mixing
System)
1)
2)
3)
4)
Open the cover (E) and check that the recovery water tank
(F) is empty, otherwise empty it with the drain hose (G).
Carefully lift the tank (A, Fig. 15).
Open the cap (B).
Replace or fill the jug (C) with any standard gallon container
of detergent suitable for the work to be performed (highly
concentrated detergents).
Do not fill the detergent tank completely, leave a few
centimeters from the edge.
WARNING!
Use
only
low-foam
and
non-flammable
detergents,
intended
for
automatic
scrubber
applications.
NOTE
To install a new jug container, determine the cap size and
if it is the smaller cap, remove the reducing adapter from
the hose cap (B). Insert the suction tube into the jug (C).
Pushdown firmly on the cap (B) and twist at the same
time to put the cap back onto the jug (C).
In case of new system, system emptied for cleaning, etc.,
wait for the hoses to fill up, before starting the Chemical
Mixing System.