Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
• E03: Inappropriate charge mode (12V mode chosen for 24V battery)
• E04: Battery defective, battery cannot retain charge
• E05: Unsuccessful desulphation (Defective battery)
• E06: Reverse connection (with error LED)
CHARGING TIME DURATION
Different battery capacity, residual voltage and charging current will all affect
charging time. The following table is for guidance in the case of a fully
discharged battery.
When charging is complete the green “CHARGED” LED will come on
.
Switch off the charger and disconnect the plug from the power socket.
Remove the leads from the battery as described on page 8 and store them
onboard the charger with the mains lead.
Battery
Size /
Ah
Approx. Time to Charge in Hours
12V 24V
2A 4A 6A 8A 10A 15A 3.5A 7.5A
421------
14 7 3.5 2.3 1.8 - - - -
25 12.5 6 4.2 3.5 2.5 - - -
30 15 7.5 5 4 3 2 15 7.5
40 20 9 6.7 5.5 4 2.7 18 9.5
50 25 10 8.3 6.5 5 3.4 20 10.5
60 30 12.5 10 8 6 4 - 16.5
100 - 15 16.7 12.5 10 6.7 - 25
120 - 26201512 8 - -
180 - - 30 22 18 12 - -
230 - - - 30 23 15.3 - -
300 - - - - 30 20 - -
400-----25--