Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
INTRODUCTION
Thank you for purchasing this CLARKE Jump-start.
The JS1100 is a rechargable power pack which can be used to start a car in
the event of a flat battery. The unit can also be used to power electrical
appliances via a cigarette lighter type socket using the adaptor supplied. The
unit also incorporates a built-in lamp and may be used as a stand alone light
source. An audible warning will sound in the event of low battery voltage, or if
the clamps are incorrectly fitted for jump starting (wrong polarity).
The integral air compressor (JS1100C only) is ideal for pumping up tyres on the
vehicle or a variety of accessories. However, for assured accuracy a
calibrated tyre pressure gauge should always be used.
Before attempting to use this product, please read this manual thoroughly and
follow the instructions carefully. In doing so you will ensure the safety of yourself
and that of others around you, and you can look forward to your purchase
giving you long and satisfactory service.
Please keep these instructions in a safe place for future reference.
SPECIFICATIONS
Please note that the details and specifications contained herein, are correct
at the time of going to print. However, CLARKE International reserve the right
to change specifications at any time without prior notice.
Item Specification
Weight 7.9 kg (JS1100), 8.4 kg(JS1100C)
Insulation Class (Charger) Class II
Max Output Current Starting 500A
Peak 1100A
Battery Type Sealed re-chargeable lead-acid
12V/18Ah
Auxiliary (Lighter) Socket output 12V dc /15A
USB Power Supply 5 V dc - 1.1A
Estimated engine starting capacity Up to 2.5 litres diesel or
3.0 litres (petrol)
Air Compressor Max output (JS1100C) 17.9 bar (260psi)
Compressor Duty Cycle 50% (10 min on/10 min rest) but not
more than 6 cycles. (after which wait
2 hours before repeating).