PREVENTION OF ELECTRIC SHOCK
1. Never use the generator in wet conditions unless it is well protected/
covered. Under these conditions, adequate ventilation MUST be provided.
2. Never operate the generator with wet hands.
3. Never use
water or any other liquids to clean the generator.
ADDITIONAL SAFETY RULES FOR GENERATORS
1. Always ensure the applied load does not exceed the generator rating.
Overloading the generator is dangerous and could cause serious
damage.
2.
Always
disconnect the generator when carrying out any maintenance.
3. Always ensure the generator reaches operating speed before connecting
a load.
4. Never
allow the generator to run out of fuel when a load is connected.
5. Never
transport the generator with fuel in the tank.
6. Do Not
connect to a commercial or residential power supply; e.g. ring
main.
7. Never allow the generator air vents to become blocked.

Related product manuals