WARNING!
TO DISPERSAL
SEWER LINE
FUSION ALARM PANEL
BLOWER
RISER AND LID
FUSION
OPTIONAL SEPTIC TANK INSTALLATION
MAY BE REQUIRED BY LOCAL
OR STATE REGULATIONS
AIR LINES
CLEANOUT
ALARM FLOAT
CONDUIT INSTALLED
BY CONTRACTOR
WHERE APPLICABLE
Figure 11 - Typical Fusion
®
Layout
sk2650
1. The blower must be connected to a grounded, metallic, permanent wiring system, or an
equipment-grounding terminal or lead on the product.
2. Place the blower where it is easily accessible for maintenance and inspection.
3. Install the blower in an area where it will be protected from damage and inundation. Also
make certain the location has good ventilation.
4. Install the blower on a foundation that is level and solid.
5. Excavate trenches for two air lines from blower to the unit.
6. Install two separate 1/2" (13 mm) air lines from the blower to the unit. Length of piping
must be less than 17' (5 m). If distances from 17' (5 m) to 33' (10 m) are required, use
3/4" (19 mm) diameter piping (Figure 12). If longer air lines are needed, consult the
factory.
7. The blower is provided with two discharge ports. The blower label is color-coded with the
aeration outlet port being BLUE (main) and the backwash (skim) outlet port being RED
(Figure 12).
8. The air port inlets on the Fusion
®
are also color-coded, BLUE for aeration and RED for
backwash (Figure 12).
9. Attach the barbed end of each PVC tee (included in the blower box) to the blower using the
rubber elbows (Figure 12).
10. Attach the small diameter black air tubing (included in the blower box) to barbed tting
on PVC tee. Black air tubing and blower power cord should be routed to the alarm panel
through conduit. Attach the two black air tubing lines to the two air pressure sensor barbed
ttings in the alarm panel (Figure 12).
11. Connect the remaining end of each PVC tee to the
airlines installed in Step 6.
12. Install the Fusion
®
blower at an elevation where the
air line outlets are located above the elevation of the
Fusion
®
air line inlets (Figure 12).
BLOWER INSTALLATION AND PLACEMENT
TO PREVENT ELECTRICAL SHOCK
FROM BACK-SIPHONING, LOCATE
THE PUMP ABOVE THE WATER
LEVEL.
DECORATIVE ROCK CONFIGURATION
INTERIOR CONFIGURATION
DRILL HOLES FOR
BLOWER MAKE UP AIR
Figure 12
ELECTRICAL SHOCK
HAZARD
!
WARNING
DECORATIVE ROCK CONFIGURATION
INTERIOR CONFIGURATION
RED AIR
LINE
BLUE AIR
LINE
HIGH WATER FLOAT CONDUIT
TO BE INSTALLED BY
CONTRACTOR
(WHERE APPLICABLE)
FUSION UNIT
AIR LINE FROM PUMP
1/2" SCH 40 PVC
BULK HEAD FITTINGS
RUBBER
ELBOWS
POWER
CORD
RED AIR
LINE
BLUE AIR
LINE
CONDUIT TO PANEL
AIR LINE
TO PANEL
ADAPTER
BLOWER
AIR LINES
TO PANEL
SPRING
CLAMPS
DRILL HOLES FOR
BLOWER MAKE UP AIR
ALARM FLOAT
CONDUIT
SEAL AFTER LINE
INSTALLATION
AIR SENSOR LINE
1/2 X 3/4 REDUCER
INSTALL BUSHING IF AIR
LINE IS LESS THAN 17'
TO UNIT
GLUE
FITTINGS
BLOWER
sk2639