C3X C5X
Electrical
data
P1 Rated power (W)
650W 850W
P2 Rated power (W) 375W 475W
Rated voltage
220V-240V
Mains frequency (Hz) 50Hz
Rated current
2.6 A @ 230V 3.4 A @ 230V
Power cable type
HS-05
Capacitor (uF) 10uf 20uF
Hydraulic
data
Max flow (lpm / m3/h)
55 lpm
3300. l/h
63 lpm
3780. l/h
Max head (m)
35m 43m
Start Pressure (Bar)
Default cut-in 1.5 bar
Stop Condition Cut out on no flow <1.2 lpm
Max suction depth (m/min)
8m/<3min
Range of
use
Length of power cable (m) 1.5m
Motor protection level
Class F
Protection class
IPX4
Impellers Single, Technopolymer
Filter
Integrated, 1mm particles
Liquid temperature range (°C) 3°C to 35°C
Environmental temperature (°C) -10°C to 40°C
Max diameter of particle 2mm
Motor
Air cooled, 2 pole
Outlet
1” BSP
Package dimension 640 x 325 x 193mm
Weight Gross weight (kg)
9 kg
This pump must never be used to pump salt water, sewage, flammable, corrosive or
explosive liquids (e.g. petroleum oil, petrol, and thinners), grease, oils or foodstuffs.
If the pump has been used with substances that tend to form a deposit, or with water
containing chlorine, rinse it after use with a strong jet of water to prevent formation of
deposits or encrustations which could reduce the performance of the pump.