25
PROBLEM
CAUSE
SOLUTION
Plugged orifice and/or screen
Unplug or replace orifice and/or screen
in the cleaning tool.
Inlet strainer is clogged.
Inspect all lines, remove accumulated
debris which is blocking proper flow.
Loss of solution
Replace and defective hoses. Remove,
volume at cleaning
inspect, and clean the strainer screen.
tool orifice.
De-scale unit and install a water
softener, if necessary.
Water gauge reads
Defective quick-connect on
Replace defective quick-connects(s)
normal.
one or more of the high
on high pressure hose(s).
pressure hoses.
Cleaning tool valve is
Repair or replace valve.
malfunctioning.
Hose inner lining is
Remove restriction or replace hose.
constricted.
Air leak in chemical supply
Check for air leaks. Replace faulty
line, metering valve.
parts.
Vacuum gauge is giving an
Examine the tubing between the
improper reading.
vacuum relief valve and the vacuum
gauge and remove any blockage.
Vacuum hose(s) is damaged,
Inspect hose(s), repair or replace.
causing a suction leak.
Waste tank gaskets not
Inspect the gasket. Repair seal or
sealing properly, not
replace. Re-position lid(s).
positioned properly.
Plugged vacuum hose or
Unplug vacuum hose or lint basket.
Loss of vacuum
vacuum plumbing between
vacuum inlet and lint
While cleaning, the
basket.
Vacuum is not up
to
Waste tank filter or lint
Clean or replace filter. Clean lint
specification.
basket is plugged.
basket.
Engine RPM is
Loose vacuum pump drive
Tighten the drive belts.
Normal.
Belts.
Waste tank drain valve is
Drain the waste tank. Close drain
damaged or left open, causing
valve, if open. Remove the dump
a vacuum leak.
Valve and, after inspecting, replace
the defective components.
Vacuum relief valve requires
Re-adjust the vacuum relief valve. If
adjustment or has a vacuum
the vacuum does not increase, remove
leak due to damaged
and inspect the relief valve diaphragm.
Diaphragm.
If damaged, replace.
Vacuum pump is worn out.
Replace the vacuum pump.