TROUBLESHOOTING
Symptom: Machine does not run! No power to the machine!
Problem: Batteries not correctly installed in machine.
Solution: Install batteries correctly in machine. Follow instructions give above (see page 8 + 11).
Problem: Internal fuse or FI protection switch tripped.
Solution: Check internal fuse and FI protection switch.
Problem: Power supply interrupted.
Solution: Have power supply checked by authorized technician.
Problem: Frayed cables, damaged plug or loose internal wiring.
Solution: Have an authorized service technician check cord and replace if necessary. Have an
authorized service technician open switch panel and check for loose wire connection.
Problem: Brush motor protection switch tripped.
Solution: Allow motor to cool, press motor protection switch pushbutton, put less clean water into
the tank.
Problem: Discharge signal transmitter has activated.
Solution: Charge batteries.
Symptom: Insufficient vacuuming power! Loss of vacuum!
Problem: Tank cover/dome not properly seated or gasket on dome damaged/worn out.
Solution: Reseat tank cover correctly or replace gasket.
Problem: Vacuum hose and squeegee assembly is clogged up with dirt, or hose is not correctly
inserted into squeegee assembly.
Solution: Remove dirt and re-attach vacuum hose.
Problem: Filter in recovery tank is clogged up.
Solution: Clean filter with clean water.
Problem: Recovery tank drain hose not properly closed.
Solution: Close properly.
Problem: Wrong angle of squeegee assembly.
Solution: Adjust angle of squeegee assembly.
Problem: Defective vacuum motor.
Solution: Have an authorized service technician replace vacuum motor.
Symptom: Poor cleaning performance!
Problem: Worn brush or pads.
Solution: Replace brush or pads.
Problem: Improper chemical for cleaning job or improper dilution.
Solution: Change chemical or adjust dilution.