Safety, Operation and Maintenance Manual for Falcon (RA 530 B); Version 1.0
10
OPERATING THE AUTO-SCRUBBER (cont.)
REPLACING THE CYLINDRICAL BRUSH
To remove the cylindrical brush, remove two
screws on the metal plate on the right side of the
machine (C3). Pull the metal plate outwards.
The brush can be removed from the metal plate
by pulling it off. Mount the new brush onto the
metal plate and place back into the housing.
Make sure that the connections for correct fitting
of the brush, which are at the other end of the
housing fit onto the brush.
When the metal plate is correctly fitted, tighten
the two screws securely back into position.
WORKING WITH EXTERNAL TOOLS/ACCESSORIES
Disconnect the hose between the recovery
tank cover and the squeegee assembly.
Attach the vacuum hose used with the
external tool to the connector of the recovery
tank.
Connect the solution hose used with the
external tool to the quick disconnect (C2).
Set the solution flow rate (C1) to position „0“.
Connect the external tool to the hoses.
Push button for the pump (B6) and for the
vacuum motor (B4).
Hard-to-reach areas, stairs and corners can
now easily be cleaned with the external tool.
FINISHING THE JOB
Turn off the solution flow (B6).
Turn off brushes (B5).
Turn off vacuum motor (B4).
Raise squeegee with lever (A10).
Tilt the machine backwards and place it on
the kickstand (F1) underneath the front of the
machine. Remove brushes or pads and pad
driver and rinse thoroughly with clean water.
Remove machine from kick-stand back to
normal upward position.
Rinse and clean recovery tank cover with
clean water.
Clean below the machine with a damp cloth.
Fill solution tank with approximately 1 gallon
of clean water.
Attach water drain hose to connector (C2).
Set the solution flow rate (C1) to „0“.
Turn on pump (B6).
Pump out coming water into a bucket or a
drain.
Clean entire machine with a damp cloth.
Remove squeegee assembly from the holder
and clean it.