FOR-22 4-WIRE INTERFACE
4-2
POWER SUPPLY
Supplied by the a PSU-101 power supply
Voltage Required ± 8 volts DC Unregulated
Current Required 30 milliamps (per supply, no LEDs or
relays active)
160 milliamps (positive supply, LEDs
and relays active)
140 milliamps (negative supply, all
LEDs and relays active)
CONNECTORS (ON REAR OF IMF-3 FRAME)
RJ-45 "To Matrix" Connectors ---------------------- 2
DB-9M "Interface I/O" Connectors --------------- 2
OPERATING ENVIRONMENT
Temperature Between 0 and 70° C (32-150° F)
PACKAGE DIMENSIONS
Frame Slot Usage 1 slot of IMF-3 or IMF-102 frame
Weight 0.54 lb (0.22 kg)
Notice About Specifications
While Vitec Group Communications makes every attempt to maintain the
accuracy of the information contained in its product manuals, that information
is subject to change without notice. Performance specifications included in this
manual are design-center specifications and are included for customer guidance
and to facilitate system installation. Actual operating performance may vary.