EasyManua.ls Logo

ClearOne CONVERGE PRO 2 Series - User Manual

ClearOne CONVERGE PRO 2 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Reference Manual
CONVERGE PRO 2 Serial Commands
DOC-0293-001 v.1.9 October 2020
Supported Products:
CONVERGE Pro 2 Devices

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ClearOne CONVERGE PRO 2 Series and is the answer not in the manual?

Summary

1. Concepts

1.1 Introduction

This document describes the serial commands for CONVERGE Pro 2.

1.2 Connection to the Device

You can connect to a CONVERGE Pro 2 device via its serial port or via telnet session.

1.3 End Points

End Points are audio channels that can be controlled and linked using CONVERGE Pro 2.

1.4 Syntax Conventions

The syntax conventions described in this section apply throughout this manual.

1.5 Input;Output

Using the serial port, you can send commands to a CONVERGE Pro 2 box (input), and the box sends return information (output).

1.6 Text vs. Numerical Parameters

Most parameters (unless noted otherwise) can be expressed as either text or as numbers.

1.7 Read;Write Modes

Many commands can function as both write commands (sending information to the box) or read commands (requesting information from the box).

1.8 Channel Labels and Groups

CONVERGE Pro 2 lets you create channel labels and channel groups to refer to channels within serial commands.

1.9 CP2 Touch Panel Controller and Serial Commands

The CP2 Touch Panel Controller can be used to mute the input channel or change the volume.

Chapter 2 - Reference

2.1 STACK

Changes settings for a group of connected CONVERGE Pro 2 boxes.

2.2 BOX

Gets information about and configures a particular CONVERGE Pro 2 box.

2.3 ROOM

Creates custom partition configurations for rooms that have dividers, and can therefore be partitioned in various ways.

2.4 EP

Configures an endpoint channel.

2.5 RAMP

Ramps the gain of an end point up or down in specified increments.

2.6 MT

Creates or removes crosspoint connections between input and output end points, and specifies crosspoint attenuation and type.

2.7 CLRMATRIX

Clears all settings generated using the MT command.

2.8 FILTER

Send all the filter settings to an end point.

3. Change History

Rev 1.9, October 2020

Topics Added and Edited for Rev 1.9, October 2020.

Rev. 1.8, March 2018

Topics Added and Edited for Rev 1.8, March 2018.

Rev. 1.7, March 2018

Topics Added and Edited for Rev 1.7, March 2018.

Rev. 1.6, October 2017

Topics Added and Modified for Rev 1.6, October 2017.

Summary

1. Concepts

1.1 Introduction

This document describes the serial commands for CONVERGE Pro 2.

1.2 Connection to the Device

You can connect to a CONVERGE Pro 2 device via its serial port or via telnet session.

1.3 End Points

End Points are audio channels that can be controlled and linked using CONVERGE Pro 2.

1.4 Syntax Conventions

The syntax conventions described in this section apply throughout this manual.

1.5 Input;Output

Using the serial port, you can send commands to a CONVERGE Pro 2 box (input), and the box sends return information (output).

1.6 Text vs. Numerical Parameters

Most parameters (unless noted otherwise) can be expressed as either text or as numbers.

1.7 Read;Write Modes

Many commands can function as both write commands (sending information to the box) or read commands (requesting information from the box).

1.8 Channel Labels and Groups

CONVERGE Pro 2 lets you create channel labels and channel groups to refer to channels within serial commands.

1.9 CP2 Touch Panel Controller and Serial Commands

The CP2 Touch Panel Controller can be used to mute the input channel or change the volume.

Chapter 2 - Reference

2.1 STACK

Changes settings for a group of connected CONVERGE Pro 2 boxes.

2.2 BOX

Gets information about and configures a particular CONVERGE Pro 2 box.

2.3 ROOM

Creates custom partition configurations for rooms that have dividers, and can therefore be partitioned in various ways.

2.4 EP

Configures an endpoint channel.

2.5 RAMP

Ramps the gain of an end point up or down in specified increments.

2.6 MT

Creates or removes crosspoint connections between input and output end points, and specifies crosspoint attenuation and type.

2.7 CLRMATRIX

Clears all settings generated using the MT command.

2.8 FILTER

Send all the filter settings to an end point.

3. Change History

Rev 1.9, October 2020

Topics Added and Edited for Rev 1.9, October 2020.

Rev. 1.8, March 2018

Topics Added and Edited for Rev 1.8, March 2018.

Rev. 1.7, March 2018

Topics Added and Edited for Rev 1.7, March 2018.

Rev. 1.6, October 2017

Topics Added and Modified for Rev 1.6, October 2017.

ClearOne CONVERGE PRO 2 Series Specifications

General IconGeneral
Sample Rate48 kHz
Bit Depth24-bit
NetworkEthernet
ExpansionYes
Power100-240V AC, 50-60Hz
TelcoOptional
Channels8
Operating Temperature0°C to 40°C
Humidity10% - 90% Relative Humidity, Non-condensing

Related product manuals