clevelandvibrator.com
4544 Hinckley Industrial Pkwy.
Cleveland, OH 44109
216-241-7157
800-221-3298
Fax 216-241-3480
DC VIBRATORS MANUAL
DC Vibrator Manual
Installation, Manual & Maintenance
The Cleveland Vibrator Co. line of DC
Electric Vibrators for Truck & Trailer
Unloading applications feature a wide
range of force outputs and construction
types for handling tougher material ow
challenges. Our DC Vibrators comes
in forces from 80 lbf. all the way up to
3500 lbf., making this product line a
perfect solution for handling any load
size within your truck or trailer hopper,
spreader or screener.
WHAT'S INSIDE
Electrical Requirements
Wiring Instructions
Installation Procedures
Mounting Locations
Performance Data
Troubleshooting
Question and Answer IconNeed help?

Do you have a question about the Cleveland DC and is the answer not in the manual?

Summary

Installation

Mounting on Truck Bed

Instructions for mounting vibrators on truck beds using channel iron, focusing on proximity to material flow issues.

Vibrator Orientation

Guidance on mounting vibrator orientation with the shaft horizontal for proper material flow direction.

Single Vibrator Installation

Procedure for installing a single vibrator on a sloping wall, specifying stiffener placement.

Three Vibrator Installation

Steps for installing three vibrators on a sloping wall at 120° intervals and specific distances from discharge.

Multiple Vibrator Guidelines

Guidance on selecting and using multiple vibrators based on hopper diameter for optimal material flow.

Two Vibrators on Round or Square Hoppers

Installation method for two vibrators on round or square hoppers, specifying placement and spacing.

Two Vibrators on Rectangular Hoppers

Installation method for two vibrators on rectangular hoppers, detailing placement on long walls.

Proper Welding Tips

Wiring Instructions

Operating Requirements

Specifies voltage, amperage, and maximum ambient temperature requirements for DC vibrators.

Truck Dump Body Applications

Advice for using vibrators on truck dump bodies, including engine running and accessory use.

Controlling Vibrator Speed

Information on using a rheostat to control vibrator speed and enhance bearing life.

Wiring to Power Source and Switching

Detailed steps for connecting vibrators to power sources and switches, including voltage matching.

Performance Data

Maintenance Checks

Bolt Torque Chart

Troubleshooting