f) Consult your doctor before use as some medication may induce drowsiness while other medication may
affect heart rate, blood pressure, and circulation.
g) To accurately check the water temperature we recommend the use of a calibrated digital thermometer
or mercury thermometer, ensuring this matches with the spa control panel (see page 10 regarding how
to operate your hot tub).
• Hypothermia occurs when the internal temperature of the body reaches a level several degrees above
the normal body temperature of 37°C (98.6°F). The symptoms of hypothermia include an increase in
the internal temperature of the body, dizziness, lethargy, drowsiness and fainting.
The effects of hypothermia include failure to perceive heat, a failure to recognise the need to exit the
CleverSpa
®
, an unawareness of impending hazards, fetal damage in pregnant women, a physical inability
to exit the CleverSpa
®
and unconsciousness resulting in the danger of drowning. WARNING – The use
of alcohol, drugs, or medication can greatly increase the risk of fatal hypothermia.
SAVE THESE INSTRUCTIONS
SPECIFIC REQUIREMENTS FOR THE SUCTION FITTING
• Required replacement of the suction fitting may only be performed by authorised representatives of Clever
Company Limited.
• This suction fitting is for surface mounted wall installation only, and can be classed as a self-contained hot
tub fitting for multiple outlet use only.
• Suction outlets must not be modified from the original position and located on seating areas or on the
backrests for such seating areas.
• When two or more suction fittings are used on a common suction line, they shall be separated
by a minimum of 3ft, or if any are located closer, they shall be located on two different planes.
• In the event that a suction outlet becomes blocked, the hot tub should not be used until the defective outlet is
fixed or replaced by an authorised representative. The remaining suction outlets serving that system shall have
a flow rating capable of the full flow of the pump(s) for the specific suction system.
• Only the pipework utilised in the original construction (OD/ID) can be used on this hot tub and cannot be
interchanged for other sizes.
• Wall mounted only.
• Suction fitting reference MX01.
• Replace within 3 installed year.
• Required replacement of the suction fitting may only be performed by authorised representatives of Clever
Company Limited.
• To protect the life of the suction fitting, the water in this hot tub should never be allowed to drop below 5
o
C, 41
o
F.
• The maximum flow rate through the suction fitting must not exceed 14 gpm.
• Before each use of the spa/hot tub, please inspect the suction fitting and its fastening for damage or tampering.
• We will state missing, broken or cracked/damaged suctions fittings must be replaced before use
• The suction fitting must be installed tightly, a loose fitting must be tightened before any use of the spa/hot tub.
• The flow rate through the suction fitting must not be increased through the introduction/use of an increased
capacity flow pump.
03
SAFETY INSTRUCTIONS
0
0.53
0.57
0.62
0.67
0.71
0.8
0.89
1.2
1.39
1.73
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0 5 10 15 20 25 30 35
Flow (GPM)
Flow vs Head Loss for Suction Fitting
Model No. MX01 (bbspa08500-20)
CLEVERSPA ETL US IM_FINAL.indd 3CLEVERSPA ETL US IM_FINAL.indd 3 07/01/2020 16:1707/01/2020 16:17