8
Press “SPEED” to select high speed or low
speed.
In fan mode, the sleep function cannot be
activated, and temperature cannot be adjusted.
Dehumidifying mode
Dehumidifying mode is used to remove humidity
from the room without additional cooling. In this
mode, you do not need to use the exhaust hose, but
the water collected must be discharged regularly.
Press “MODE” to select dehumidifying mode,
“DEHUMID” mode indicator will be illuminated
and “dh” shows on display.
In dehumidifying mode, sleep function cannot
be activated, and the fan speed is pre-set at
low and cannot be adjusted. Keep doors and
windows closed for best eect.
Note: If the unit will be used mainly
as a dehumidifier, do not connect the
exhaust hose and let the warm air return
in the room. Continuous drainage is then
necessary and more ecient.
Heating mode
In this mode, the air conditioner heats the room,
the exhaust hose is recommended to be installed to
improve the heating eciency. Install the exhaust
hose as described in the “Exhaust hose installation”
section.
Press “MODE” button to select Heating mode,
“HEAT” indicator will be illuminated.
Press “UP” or “DOWN” button to adjust
temperature (from 16ºC to 31ºC).
Press “SPEED” to select high or low fan speed.
Timer mode
This feature allows you to set a delay from 1 to 24
hours that will turn the air conditioner on or o
automatically.
In standby mode, press “TIMER” to setup the
auto start timer. Timer indicator will illuminate
when it is activated.
In power-on mode, press “TIMER” to setup the
auto stop timer. Timer indicator will illuminate
when it is activated.
Sleeping mode
Press “SLEEP” to enter into sleeping mode,
the fan speed will be changed to Low setting
automatically.
When sleeping mode turns on, in cooling mode,
the first one hour later, setting temperature will
go up 1°C, the second one hour later, setting
temperature will go up another 1°C, and then
keep the same. This is useful to prevent the
room becoming too cold during the night.
When sleeping mode turns on, in heating mode,
the first one hour later, setting temperature will
go down 1°C, the second one hour later, setting
temperature will go down another 1°C, and
then keep the same. This is useful to prevent the
room becoming too hot during the night.
Sleeping mode cannot be activated when the
unit is operated in either dehumidifying or fan
mode.
Auto restart
If there is a power failure during operation, the unit
will resume operation with the same setting (except
for Timer, Sleep and Swing) as before the power
failure. The Timer, Sleep and Swing features will be
deactivated.
Protective function
1. Overflow Protection Function
When there is excess water condensation inside the
unit, the air conditioner stops running and “Water
Full” indicator will flash, and the unit enters into
standby mode. The water condensation needs to be
drained as described in the “Water Condensation
Drainage” section.
2. Compress Protection Function
To increase the service life of the compressor, it has
a 3-minute delay booting protection function after
the compressor is turned o.
Note: the compressor can only be
restarted after 3 minutes, as a protective
measure against damage to the
compressor unit.