9. Wiring Diagrams
L
N
T1
T4
L
N
N-1
N-2
DC_FAN A
EXHUAST FAN
DC_FAN B
SUPPLY FAN
CN24 CN27
RA
E N C 1
5
3
2
1
4
ENC1
Capacity
setting
0
6
7
200
300
400
500
800
1000
1500
2000
SW1-1
COD
E
NAME
Outdoor temp.Sensor
POWER IN
220Vac 50Hz
Red
+
-~
~
BR1
Black
CN13
CN13
CN3
CN3
DC_FAN
DC_
F
AN
Module A
Module B
FM
FM
DC_FAN A
EXHUAST FAN
DC_FAN B
SUPPLY FAN
Bypass
damper
motor
CN19
Black
Red
Y/G
Blue
Xt1
27B Wired
controller
+
~
-
~
BR2
MOV
681
Blue
Brown
White
Red
Red
RB
RC
Red
R1230
R1510
PGND
AC_2
AC_1
P
Black
Red
Blue
Blue
CN8
P Q E
Show on
Tim
e
entralized controller
Unit is ON
Unit is OFF
Indoor temperature
sensor error
Outdoor temperature
sensor error
EEPROM error
DC fan motor error
Explanation
/ /
/
/
2 2
E2
4
E5(new protocol)
EF(old protocol)
6 6
E7
8 8
E6
10 10
OFF LINE
Without address
ommunication error
12
12
h ODU
E1
NOTE:
:Light ;
:Extinguish ;
:Quick flash
Operation
Flash
lam p
X Y E
CO2 Sensor
CN9
CN32 CN33
CN7
CN31 CN16
X1X2
CN26
CN21
PRO
S
W
1
S
W
2
CN14
CN15 CN20
CN10
CN34
SW1-2
SW2-1
SW2-2
SW2-3
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
14
16
18
E9
EU
FC
error with sensor board
error with CO2 sensor
wire controller
communication failure
CN8
CN9
CN32
CN33
-
D1D2E
CN7
CN3
CN4
Indoor temp. Sensor
CN21
-
HRV centralized control
HRV single unit operation
With PRO
Without PRO
Positive Pressure
Negative Pressure
SW2-2
Balance Pressure
Ip address Conflict
Ed Outdoor unit failure
1 2
ON
1 2
ON
3
1 2
ON
3
1 2
ON
3
1 3
ON
2
1 2
ON
3
1 2
ON
3
1 2
ON
1 2
ON
1 2
ON
Low static pressure
Hige static pressure
1 2
ON
3
1 2
ON
12
* Reserved
1-2
1-3
reserved
Dry contact
(Out put)
Dry contact
(In put)
CN31
CN16
CN26
CN14
CN15
CN20
Remote ON/OFF
Force to exhaust air mode
Signal for inlet air Pre-heat
Alarm
Reserved
Max voltage: 220 VAC (consistent with power
supply) / Max current: 1A
CN16 Force expulsion air mode - closed contact: function active (this input has a
higher priority than the setting given by dip-switch SW2-2 / 3);
CN26 Remote On / Off - closed contact: unit forced off / open contact: normal
management;
CN15 Alarm - contact closed: alarm active / contact open: no alarm
CN20 Signal for inlet air preheating - contact closed: function active / contact open:
function not active