Do you have a question about the CLIVET WSAT-SC 135F Series and is the answer not in the manual?
Refrigerant | R410A |
---|---|
Compressor Type | Scroll |
Power Supply | 400V/3Ph/50Hz |
Series | WSAT-SC |
Type | Air-Cooled Chiller |
Operating Temperature Range | -10°C to +45°C |
Defines the specific purpose of the unit and lists additional safety measures to prevent risks.
Warns about risks during unit movement and potential issues from improper installation.
Covers risks like burning smells, contact hazards, and electrical system safety.
Provides essential safety data for R-407C refrigerant handling and precautions.
Details the operational temperature limits for the external heat exchanger.
Details the operational temperature limits for the internal heat exchanger.
Explains the settings for safety devices and unit controls.
Instructions for checking the unit upon arrival for damage and completeness.
Outlines safety procedures and precautions for moving the unit.
Provides further handling instructions with diagrams for lifting points.
Details the installation of antivibration devices and necessary flexible joints.
Explains the modular pumping system and its different configurations (2-pump, 3-pump).
Lists electrical data (FLA, LRA, power input) for SC units at 400/3/50V.
Lists electrical data (FLA, LRA, power input) for EN units at 400/3/50V.
Provides step-by-step instructions for safely connecting the unit to the power supply.
Describes the system's modular composition and its electronic modules.
Details the LonWorks kit, gateway configuration, and network protocols.
Checks electrical parameters during operation for safety and performance.
Describes the unit's control panel, display, and basic operations.
Information on alarms, their causes, and procedures for resetting them.
Lists all alarms associated with the central control module.
Lists all alarms associated with the compressor and pump modules.
General guidelines for maintaining equipment efficiency and preventing breakdowns.
Recommends inspection schedules and key checks by authorized personnel.
Provides an introduction to tables containing refrigerant circuit operational data.
Contains pressure and temperature data for R22, R134a, R407C, and R410A refrigerants.
Continues pressure and temperature data tables for various refrigerants.
Steps to diagnose and resolve issues related to faulty probes.
Steps to diagnose and resolve issues with faulty pressure transducers.
Lists causes and checks for high and low pressure alarms.
Troubleshooting steps for compressor protection issues.
Troubleshooting steps for fan and pump protection faults.
Procedures for safely disconnecting the unit, including refrigerant recovery.
Guidelines for unit dismantling and disposal at authorized centers.