AIR-COOLED WATER CHILLERS RATED FROM 190 TO 450 KW
Библиотека СОК
Question and Answer IconNeed help?

Do you have a question about the CLIVET WSAT-SC 65D Series and is the answer not in the manual?

CLIVET WSAT-SC 65D Series Specifications

General IconGeneral
Model SeriesWSAT-SC 65D Series
CategoryChiller
RefrigerantR410A
Compressor TypeScroll
Number of Compressors2
Power Supply400V/3Ph/50Hz
Cooling Capacity65 kW
Control SystemMicroprocessor-based
Protection FeaturesOverload, Phase Failure

Summary

General Safety and Operational Guidelines

General Warnings and Instructions

Essential to observe instructions; manufacturer declines liability for damages if not heeded.

Manual Store and Expert Personnel

Store manual and wiring diagram for operator reference; installation by expert personnel.

Installation and Maintenance Precautions

Covers local regulations, power supply, packaging, inspections, faults, repairs, and modifications.

General - Unit Use and Technical Characteristics

Unit Intended Use and Safety

Details the intended use, additional safety precautions, and data updating policy.

Technical Characteristics of Standard Units

Detailed specifications for Compressor, Structure, Air/Water Exchangers, Fans, Refrigerant Circuit, and Electrical Panel.

Residual Risks

General Risks and Definitions

Defines danger areas, handling, installation, and general operational risks.

Electrical System Risks

Hazards related to power supply line, grounding, and accessible live parts.

Moving Parts and Refrigerant Hazards

Risks associated with moving parts (fans) and refrigerants (injury, toxicity, explosion).

Water System and Refrigerant Safety

Risks from water leaks and comprehensive safety information for R-407C refrigerant.

Electrical Data

General Specifications (SC Configuration)

Technical data for SC configuration: cooling, compressor, exchangers, fans, connections, dimensions, weights.

General Specifications (EN Configuration)

Technical data for EN configuration: cooling, compressor, exchangers, fans, connections, dimensions, weights.

Reception and Handling

Start-Up Procedures

Pre-Start-Up System Checks

Covers preliminary checks for electrical, aeraulic, refrigerant, water, and electrical systems.

Control - Setup and Status

Alarms and Fault Handling

Procedures for identifying, resetting, and handling alarms and faults.

Routine Maintenance

Maintenance Inspections

Recommended frequency and scope of inspections by authorized centers.

Routine Maintenance - Refrigerant Data

Troubleshooting

Probe and Transducer Fault Diagnosis

Steps to identify and resolve issues related to faulty probes and pressure transducers.

High and Low Pressure Issues

Potential causes and checks for high-pressure and low-pressure alarms.

Compressor, Fan, and Pump Protection Issues

Steps to diagnose and resolve issues related to compressor, fan, and pump protection alarms.

Related product manuals