6
B. SYSTEM SIZING REFERENCE
RESIDENTIAL SIZING CHART
CELL SIZE
POOL SIZE -
STANDARD
POOL SIZE -
HIGH DEMAND*
CHLORINE
PER DAY
320 20,000 GAL 14,000 GAL 0.78LB
540 40,000 GAL 28,000 GAL 1.35LB
TABLE 1
-
SIZING CHART
* Correct sizing of a chlorine generator is subject to the specications of each body of water, and should be carefully
evaluated for best results. Where heightened chlorine demand exists due to warmer climates, humidity, high bather load,
water features and other environmental factors, the maximum pool size should be reduced by at least 30%.
When modifying any plumbing system, it is important to evaluate the total head loss, and any impact that head loss may have
on the design of an existing plumbing system. The following chart will give specic head loss for the Powerclean Salt Cell. If
you have any questions, please contact our tech support department.
DESIGNED FLOW RATE GPM ACTUAL HEAD LOSS
20% 20 .20 Ft Water
40% 40 .41 Ft Water
60% 60 1.54 Ft Water
80% 80 2.28 Ft Water
100% 100 3.71 Ft Water
TABLE 2
-
FLOW RATE VS HEAD LOSS