Chapter 2: Operation
Setup 41
22222
Operation
Auto-Ack Test Auto-acknowledgement of test DSC messages.
OFF or ON (default)
Auto-Ack Polling Auto-acknowledgement of polling DSC messages.
OFF or ON (default)
Auto-Ack
Position
Auto-acknowledgement of position DSC messages.
OFF (default) or ON
Auto-Ack
Individual
Auto acknowledgement of individually addressed, non
distress DSC messages
OFF or ON (default)
Non-Distr.
Inactivity
Inactivity time-out to exit non-distress functions (e.g. in
setup) without automatic time-out (OFF):
Range: OFF, 1 to 30 minutes, in 1 min. steps
Default: 15min.
Distress
Inactivity
Inactivity time-out for received distress DSC automated
procedures without automatic time-out:
Range: OFF, 1 to 30 minutes, in 1 min. steps
Default: OFF
Comm
Inactivity
Inactivity time-out of non DSC communication (VHF).
Range: 10 to 600 seconds, in 10 s steps
Default: 30sec
Non-
Distr.Alarms
Non-distress DSC alarms
OFF: Disabled
ON: Enabled (default)
Medical
transport
ON: This option is available in DSC calls of the type
Urgency.
OFF (default)
Neutral crafts ON: This option is available in DSC calls of the type
Urgency.
OFF (default)
DSC setting Description